Comparison of the Measurement Uncertainty of Thermoluminescence Dosimeters (TLD-100 and GR-200) in Clinical Radiotherapy Energies.
Bahare Sadeghi, Reza Pur Imani, Hossein Kiani, Mohamad Reza Bayatiani, Fatemeh Seif
Department of Physics, Arak University, Arak, Iran. · Atomic Energy Organization of Iran, Tehran, Iran.
Key points
From the paper's conclusion- The GR-200 exhibits higher sensitivity for low-dose radiation detection; however, its greater uncertainty makes TLD-100 more suitable for clinical and personal dosimetry applications, where precision and reliability are paramount.
Abstract
BACKGROUND: Accurate determination of individual radiation doses is critical in dosimetry, and international standards emphasize the importance of reporting measurement uncertainties. Neglecting measurement uncertainty undermines the reliability of reported dosimetric values, as emphasized by international standards. OBJECTIVE: This study aimed to evaluate the measurement of uncertainties in two Thermoluminescent Dosimeters (TLDs)-100 and GR-200, in the dose range of 30-150 cGy. MATERIAL AND METHODS: In this experimental study, we evaluated the measurement of uncertainties in two thermoluminescent dosimeters, TLD-100 and GR-200, in the dose range of 30-150 cGy. The study investigated both random (Type A) and systematic (Type B) uncertainties. Random uncertainties include the non-uniformity of dosimeter sensitivity Element Correction Coefficient (ECC), variability in dosimeter response at zero dose, and repeatability. Systematic uncertainties include the dependence of dosimeter response on radiation energy, radiation angle, nonlinearity of dosimeter response, fading, ambient light effects, and reference calibration errors. RESULTS: The total uncertainty for TLD-100 was calculated as 10.99% at a 68% confidence level (21.99% at 95% confidence), while for GR-200, it was 13.63% at a 68% confidence level (27.26% at 95% confidence). These values are well below the 42% threshold recommended by the International Atomic Energy Agency (IAEA) for personal dosimetry services. CONCLUSION: The GR-200 exhibits higher sensitivity for low-dose radiation detection; however, its greater uncertainty makes TLD-100 more suitable for clinical and personal dosimetry applications, where precision and reliability are paramount.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Calculation and correction of the eye-lens dosemeter response at non-calibration photon energies.Radiation protection dosimetry · 2026
- Impact of a common user-derived electrometer calibration coefficient on absorbed dose-to-water determination: a multicenter uncertainty studyJournal of Radioanalytical and Nuclear Chemistry · 2026
- Thermoluminescence dosimetric properties of natural zeolite powder under 6 MV photon and 6 MeV electron irradiation.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Dosimetry with LIF:Mg,Ti (TLD-100) for locating non-paubable breast cancer using Iodine-125 seeds.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- In vivo Dose Measurement in Cervical Cancer Brachytherapy Using Dysprosium-doped Calcium Sulfate Thermoluminescent Dosimeters: A Phantom Study.Journal of medical physics · 2026
- Distance-dependent influence of scoring voxel size on Monte Carlo dosimetry of an iridium-192 HDR brachytherapy sourceEPJ Web of Conferences · 2026