Wear performance of metal and ceramic long-neck femoral head taper connections: an experimental ex vivo study.
Margarida Ribeiro de Sousa, Perttu Neuvonen, Vesa Saikko
Aalto University, Espoo, Finland. margarida.ribeirodesousa@aalto.fi. · Coxa Hospital for Joint Replacement, Tampere, Finland.
Key points
From the paper's conclusion- The long and extra-long head taper connections showed increased wear compared with that of medium heads. Although no serious damage occurred, CoCr head tapers were the most affected compared with ZTA.
Abstract
BACKGROUND AND PURPOSE: The wear performance of femoral head taper connections is important for the longevity of total hip replacement. Metal release may cause adverse tissue reactions. There are some clinical indications that long neck heads may show increased wear, but no laboratory tests have been published. We aimed to examine the wear performance of femoral head taper connections in long and extra-long neck heads. METHODS: Load frame and hip joint simulator wear tests were performed with the same stem designs as in the reference study. The CoCr and zirconia toughened alumina (ZTA) heads of 36 mm diameter were of the long or extra-long neck type. Optical and scanning electron microscopy were utilized to study wear marks, and mass spectrometry to estimate Ti and Co release. Head disassembly forces were measured. RESULTS: Our preclinical, design-specific results showed that, compared with medium necks, long and especially extra-long necks led to increased wear while maintaining an asymmetric wear pattern more widely distributed throughout the contact area. In the hip joint simulator tests, 1 neck fracture occurred. CONCLUSION: The long and extra-long head taper connections showed increased wear compared with that of medium heads. Although no serious damage occurred, CoCr head tapers were the most affected compared with ZTA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Corrosion and wear damage estimations for retrieved knee and hip implants.Npj Materials degradation · 2026
- Patterns of wear, fracture, and re-revision in ceramic-on-ceramic total hip arthroplasty: a 31-year retrieval study.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- Indications for revision following Birmingham Hip Resurfacing : insights from the largest 25-year series from a design centre.The bone & joint journal · 2026
- Effect of varying trunnion geometry of hip implant on contact mechanics under walking gait cycle: A finite element studyMaterials & Design · 2026
- Wear Scar Morphology and Distribution in Retrieved Unicondylar Knee Arthroplasty Implants: Influence of Patient and Implant Factors.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
- Prosthesis-Related Risk Factors for Trunnionosis: A Comprehensive Literature Review.Clinics in orthopedic surgery · 2026