Patterns of wear, fracture, and re-revision in ceramic-on-ceramic total hip arthroplasty: a 31-year retrieval study.
William G Blakeney, Reuben S Jeyaraj, Alan M Kop, Richard J Beaver, Moreica Pabbruwe
Department of Orthopaedics, Royal Perth Hospital, Perth, WA. Australia. · Centre for Implant Technology and Retrieval Analysis, Health Technology Management Unit, Perth, WA, Australia.
Key points
From the paper's conclusion- Ceramic fracture in CoC THA most commonly involves the acetabular liner and is associated with patient activity and implant factors. Re-revision cases demonstrate substantial third-body wear and reduced implant survival.
Abstract
INTRODUCTION: Ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is commonly used in younger and more active patients due to its low wear characteristics. However, ceramic fracture and wear-related complications remain important causes of revision. This retrieval study aimed to characterise failure mechanisms and associated patient and implant factors in revised CoC bearings. METHODS: A retrospective retrieval analysis of alumina and zirconia-toughened alumina (ZTA) CoC THA bearings revised between 1989 and 2021 was performed. Retrievals were classified as non-fractured primary revisions, fractured primary revisions, or re-revisions. Macroscopic and microscopic assessment of fracture morphology and wear patterns was undertaken. Volumetric wear and radiographic component positioning were assessed in a subset. Associations between ceramic fracture and patient activity, implant characteristics, and head size were analysed using logistic regression. RESULTS: The most common indications for revision were aseptic loosening (35.5%), pain (34.1%), ceramic fracture (17.7%), infection (13.2%), and instability (11.8%). Ceramic fracture predominantly involved the acetabular liner (34 liner fractures versus 12 femoral head fractures). Higher patient activity level was associated with increased odds of fracture (moderate activity: OR 11.8; 95% CI, 2.66-52.7; high activity: OR 5.6; 95% CI, 1.24-25.0). ZTA femoral heads (OR 0.30; 95% CI,0.13-0.66) and larger head sizes were associated with lower odds of fracture (p < 0.001). Differences in volumetric wear between materials were not significant after adjustment for time in situ. Re-revision cases demonstrated more extensive third-body wear and shorter implant survival. CONCLUSIONS: Ceramic fracture in CoC THA most commonly involves the acetabular liner and is associated with patient activity and implant factors. Re-revision cases demonstrate substantial third-body wear and reduced implant survival.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sandwich liner fracture after 21 years from revision total hip arthroplasty: a case report.Orthopedic reviews · 2026
- Ceramic component fracture following trauma in a bilateral total hip arthroplasty.Orthopedic reviews · 2026
- Comparative outcomes of Forte versus Delta ceramic bearings in total hip arthroplasty using a national database.Scientific reports · 2026
- Association between cemented and uncemented cups and risk of revision in patients aged 65 years or older following primary total hip arthroplasty: a study of 310,515 patients from the Nordic Arthroplasty Register Association.Acta orthopaedica · 2026
- Cumulative revision rates in total hip arthroplasty depending on acetabular cup fixation: an analysis from the German arthroplasty registry.Arthroplasty (London, England) · 2026
- Catastrophic acetabular wear following polyethylene liner dissociation with locking-tab damage after total hip arthroplasty: a case report.Frontiers in surgery · 2026