From the paper's conclusion- Mechanical interference during robotic-assisted S2AI screw insertion was associated with a sagittal alignment profile characterized by increased lumbar lordosis and anterior pelvic orientation. Recognition of alignment-dependent spatial constraints may improve preoperative assessment and help predict technical difficulty.
Abstract
INTRODUCTION: Although robotic-assisted spinal instrumentation enables highly accurate screw placement, mechanical feasibility constraints remain underrecognized. During sacral instrumentation, a collision between the robotic arm and the patient's body may prevent completion of S2 alar-iliac (S2AI) screw placement as planned. Alignment-related factors associated with failure of this procedure have not been clearly defined. The aim of this study was to identify spinopelvic alignment factors associated with mechanical interference during robotic-assisted S2 alar-iliac (S2AI) screw insertion. METHODS: This retrospective observational study included 17 consecutive patients who underwent planned robotic-assisted S2AI screw insertion using the Cirq robotic alignment system (Brainlab) between July 2022 and January 2026. Patients were categorized into a success group (robotic guidance completed as planned) and an interference group (robotic guidance abandoned because of mechanical collision requiring conversion to a conventional technique). Supine spinopelvic parameters, including lumbar lordosis, sacral slope, pelvic tilt, and pelvic incidence, were evaluated preoperatively. Continuous variables were compared between groups using the Mann-Whitney U test. RESULTS: Robotic guidance was successfully completed in 13 patients (76%) and discontinued because of mechanical interference in 4 (24%). Supine lumbar lordosis was significantly greater in the interference group (median 58.5° vs. 27.6°, p=0.0008). All cases in the interference group demonstrated lumbar lordosis >50°, whereas none in the successful group exceeded this value (p<0.001). Pelvic tilt demonstrated complete separation between groups, with negative values in all interference cases and positive values in all successful cases (p=0.0008). Sacral slope was significantly higher in the interference group (p=0.0055), whereas pelvic incidence and skin-to-bone distance were not associated with interference. CONCLUSIONS: Mechanical interference during robotic-assisted S2AI screw insertion was associated with a sagittal alignment profile characterized by increased lumbar lordosis and anterior pelvic orientation. Recognition of alignment-dependent spatial constraints may improve preoperative assessment and help predict technical difficulty.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy and influencing factors of robot-assisted sacroiliac screw placement: a comparative study of short versus trans-cortical screws.Journal of robotic surgery · 2026
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026
- The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Robotic-Assisted Spinal Instrumentation from C1 to S1 Experience of a UK Neurosurgical Tertiary Referral Centre.Journal of clinical medicine · 2026
- The influence of robotic assistance on hidden blood loss in the treatment of posterior pelvic ring injuries with sacroiliac screw fixation: A retrospective cohort study.Medicine · 2026
- Accuracy of robot-assisted cortical bone trajectory pedicle screw placement: CT-based retrospective cohort study.Acta orthopaedica Belgica · 2026