Accuracy and influencing factors of robot-assisted sacroiliac screw placement: a comparative study of short versus trans-cortical screws.
Wenhui Zhang, Yuanyuan Zhang, Xiaoyuan Wu, Yuping Yang, Yuhong Ma, Huiping Tai, Hui Zhang, Kejun Yin
Gansu Provincial Hospital, Lanzhou, China. · Affiliated Hospital of Gansu University of Chinese Medicine, Lanzhou, China.
Key points
From the paper's conclusion- To systematically evaluate the accuracy of robot-assisted sacroiliac screw placement, compare the precision difference between short screws and trans-cortical (through-and-through) screws, and analyze factors associated with screw malposition.
Abstract
To systematically evaluate the accuracy of robot-assisted sacroiliac screw placement, compare the precision difference between short screws and trans-cortical (through-and-through) screws, and analyze factors associated with screw malposition. A retrospective analysis was conducted on 149 patients with pelvic fractures who underwent robot-assisted sacroiliac screw placement at Gansu Provincial Hospital from January 2021 to October 2025. A total of 149 sacroiliac screws (93 short, 56 trans-cortical) were included. Screw accuracy was assessed by postoperative pelvic CT using the Smith grading system. Functional outcomes were evaluated by Majeed score at 6 months. Univariate analysis was used to explore risk factors for malposition, but results are presented as exploratory due to the limited number of events. The overall accuracy rate was 98.0% (146/149). The accuracy of short screws (98.9%, 92/93) was significantly higher than that of trans-cortical screws (96.4%, 54/56, P = 0.035). All malpositioned screws were Smith grade I (cortical breach ≤ 2 mm). Univariate analysis suggested that screw type (P = 0.035) and BMI ≥ 30 kg/m² (P = 0.031) were associated with malposition, but these findings are exploratory and should be interpreted with caution, as they are based on only five malposition events. The excellent-good rate of Majeed score at 6 months was 91.4% (85/93) in the short screw group and 85.7% (48/56) in the trans-cortical group (P = 0.097). Robot-assisted sacroiliac screw placement demonstrates excellent overall accuracy. Short screws show a potential accuracy advantage over trans-cortical screws. However, given the small number of malposition events and the exploratory nature of the analysis, these results should be interpreted cautiously. The most common technical cause of malposition was oblique bone surface at the entry point, which deserves greater attention as a modifiable factor. Larger prospective studies are needed to confirm these preliminary findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sagittal Alignment-Dependent Mechanical Interference during Robotic-Assisted S2 Alar-Iliac Screw Insertion.Spine surgery and related research · 2026
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026
- Accuracy of robot-assisted cortical bone trajectory pedicle screw placement: CT-based retrospective cohort study.Acta orthopaedica Belgica · 2026
- The influence of robotic assistance on hidden blood loss in the treatment of posterior pelvic ring injuries with sacroiliac screw fixation: A retrospective cohort study.Medicine · 2026
- Impact of surgeon experience on the safety and accuracy of robot-assisted vs. navigation-guided percutaneous pedicle screw placement: a matched cohort study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026