Robotic-Assisted Spinal Instrumentation from C1 to S1 Experience of a UK Neurosurgical Tertiary Referral Centre.
Asfand Baig Mirza, Wajiha Rauf, Ibrahim Muhyiddin Muhammad, Feras Fayez, Ariadni Georgiannakis, Amisha Vastani, Varinder Singh Alg, Anjum Qureshi,
Department of Neurosurgery, Queen's Hospital, Romford, Barking, Havering and Redbridge University Hospitals NHS Trust, Romford RM7 0AG, UK. · Barts and The London School of Medicine and Dentistry, London E1 2AD, UK.
Key points
From the paper's conclusion- The findings suggest a fluoroscopy learning curve threshold around case 30.
Abstract
Background: Robotic-assisted spinal instrumentation is increasingly used to support implant placement, reduce radiation exposure, and improve operative workflow. However, UK NHS data describing early programme experience across elective and emergency practice remain limited. This study aimed to evaluate the feasibility, safety profile, and early learning curve of robotic-assisted spinal instrumentation in an unselected UK NHS cohort. Methods: A retrospective, single-centre, single-arm observational cohort study was conducted, including the first 50 consecutive patients treated from programme inception between June 2024 and January 2026. No exclusion criteria were applied, and each record represented one patient and one operation. Missing data were not imputed, and denominators were reported per variable. Learning curve effects were assessed using Spearman correlation and cumulative sum analysis. Wilson 95% confidence intervals were reported for complication rates. Results: The mean age was 61.9 years; 50% were male; mean body mass index was 29.0; and median Charlson Comorbidity Index was 3. Indications were degenerative disease in 74%, trauma in 24%, and deformity in 2%. Emergency admissions accounted for 18/50 cases. Robot-specific adverse events included abandonment or conversion in 2/50 cases and system malfunction in 1/50. Surgical complications occurred in 7/50 patients. On surgeon-reviewed routine post-operative imaging, no screw malpositions required revision and no durotomies or vascular injuries were recorded; this represents a clinical revision rate rather than a formal radiological measure of screw accuracy, for which blinded Gertzbein-Robbins grading was not performed. Cumulative sum analysis suggested a potential fluoroscopy change point around case 30, with the median fluoroscopy events falling from 151 to 16 thereafter. Emergency cases involved more instrumented levels, longer operative times, and more open surgery than elective cases. Conclusions: Robotic-assisted spinal instrumentation was feasible across a diverse UK NHS caseload from C1 to S2, with a low observed complication rate. The findings suggest a fluoroscopy learning curve threshold around case 30. Larger comparative studies with formal radiological accuracy assessment are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026
- Off-Hours Robotic-Assisted Spine Instrumentation in a Teaching Hospital: Feasibility Under Increased Emergency and Workflow Burden.Journal of clinical medicine · 2026
- Accuracy and influencing factors of robot-assisted sacroiliac screw placement: a comparative study of short versus trans-cortical screws.Journal of robotic surgery · 2026
- Robotic-Assisted Total Hip Arthroplasty: Implications for Surgical Practice and Operating Theatre Design.Medicina (Kaunas, Lithuania) · 2026
- Robotically equipped 3D hybrid operating room in spine and trauma surgery - updated experience in 359 patients and 2080 screws.Journal of robotic surgery · 2026
- Beyond accuracy: is reproducibility the case for robotics in spinal trauma surgery?Journal of robotic surgery · 2026