Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study.
Jie-Lin Huang, Li-Juan Li, Mei-Ling Wang, Ji-Qing Zhu, Li-Zhou Dou, Yu-Meng Liu, Yu-Da Zhao, Xue Zhang,
Department of Endoscopy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 17 Panjiayuan South Lane, Chaoyang District, Beijing, 100021, China, 86 10 8778 7606. · Department of Otorhinolaryngology, The People's Hospital of Wenshan Prefecture, Wenshan, Yunnan, China.
Key points
From the paper's conclusion- Vir-NBI pretraining did not demonstrate incremental value over WLI for real-NBI classification. External learning curves favored WLI with small real-NBI training sets. Test-domain dependence suggests that compatibility with real-NBI may contribute to performance differences.
Abstract
BACKGROUND: Pathology-labeled optical narrow-band imaging (NBI) is difficult to assemble for laryngeal lesion classification. Translating existing white-light imaging (WLI) into virtual NBI (Vir-NBI) may improve learning from limited real-NBI data, but its value beyond that of the original images is uncertain. OBJECTIVE: This study aimed to determine whether Vir-NBI pretraining improves real-NBI classification or label efficiency compared with pretraining on the same pathology-labeled WLI. METHODS: This multicenter study compared ResNet-50 classifiers pretrained on pathology-labeled WLI or paired Vir-NBI images generated by a frozen, region-of-interest-guided CycleGAN (cycle-consistent generative adversarial network). The primary outcome was the image-level area under the receiver operating characteristic curve (AUC) difference (Vir-NBI minus WLI). Label efficiency was evaluated in these external cohorts with 10 to 100 labeled real-NBI patients and 25 paired training runs per sample size. Color-matched augmentation and paired test-modality analyses examined the influence of color change and test modality. Prospective temporal validation and a 12-clinician assessment evaluated patient-level performance and perceived image quality. RESULTS: The CHCAMS (National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College) cohort comprised 1245 patients with 8476 paired WLI-Vir-NBI images. External validation included 182 patients from CHSZCAMS (Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College) and 129 from People's Hospital of Wenshan Prefecture (WSPH). External image-level AUCs were 0.806 with WLI and 0.787 with Vir-NBI (difference -0.019, 95% CI -0.047 to 0.008; P=.17). With 10 labeled real-NBI patients, external patient-level AUCs were 0.843 and 0.773, respectively (difference -0.070, 95% CI -0.116 to -0.029; Holm-adjusted P=.006). The normalized area-under-the-learning-curve difference across 10 to 100 patients favored WLI (-0.049, 95% CI -0.090 to -0.011; Holm-adjusted P=.01). Color-matched WLI augmentation yielded higher external image-level AUC than with Vir-NBI (0.774 vs 0.739; difference 0.036, unadjusted 95% CI 0.004-0.070). In the 58-case examination-linked cohort, relative Vir-NBI performance improved on translated test images (primary-model interaction 0.235, unadjusted 95% CI 0.080-0.390); fixed-duration and all-view sensitivity analyses had case-level CIs that included 0. In the CHCAMS prospective validation cohort (138 patients), patient-level AUCs were 0.846 (95% CI 0.775-0.910) and 0.844 (95% CI 0.777-0.905), respectively. WLI identified 90.9% (60/66) of high-risk patients, compared with 81.8% (54/66) with Vir-NBI, reflecting 6 discordant patients (exact McNemar P=.03; Holm-adjusted P=.06). Among 100 image pairs from the CHCAMS source cohort, clinicians rated plausibility as 4 to 5 in 86.9% (1043/1200) of ratings; intraclass correlation coefficients for the mean ratings of 12 clinicians ranged from 0.398 (95% CI 0.265-0.497) to 0.583 (95% CI 0.471-0.659). CONCLUSIONS: Vir-NBI pretraining did not demonstrate incremental value over WLI for real-NBI classification. External learning curves favored WLI with small real-NBI training sets. Test-domain dependence suggests that compatibility with real-NBI may contribute to performance differences.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enhanced Vision Transformer with Local Feature Refinement for Fine-Grained Vocal Fold Lesion ClassificationElectronics · 2026
- An interpretable multi-instance learning method for accurate differentiation of malignant and benign laryngeal lesions in laryngoscopy.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Locally deployed general-purpose vision-language model for assessing the PD-L1 tumour proportion score in non-small cell lung cancer: a diagnostic concordance study in a community pathology department.Revista espanola de patologia : publicacion oficial de la Sociedad Espanola de Anatomia Patologica y de la Sociedad Espanola de Citologia · 2026
- A Multimodal Large Language Model Framework for Clinical Subtyping and Malignant Transformation Risk Prediction in Oral Lichen Planus: A Paired Comparison With Expert CliniciansInternational Dental Journal · 2025
- Attention-Guided Hybrid Deep Learning Framework for Automated Oral Lichen Planus Classification.European journal of dentistry · 2026
- Resolution-Aware Cross-Modality Evaluation of CFP-Pretrained Retinal Vision-Language Models for Ultra-Widefield Diabetic Retinopathy Grading.Journal of imaging informatics in medicine · 2026