An interpretable multi-instance learning method for accurate differentiation of malignant and benign laryngeal lesions in laryngoscopy.
Biao Xu, Miao Zhang, Shuai Jiang, Guilin Sun, Chaobing Gao
Anhui University of Chinese Medicine, Hefei, Anhui, China. · The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China.
Key points
From the paper's conclusion- The proposed IMIL-Net provides a high-accuracy, interpretable, and clinically-aligned diagnostic solution. By analyzing complete patient examinations and providing a statistically validated decision-making process, this model represents a trustworthy tool for integration into the clinical otolaryngology workflow.
Abstract
BACKGROUND: Laryngeal cancer is a significant global health issue with high mortality, and early diagnosis is critical for survival. Developing accurate diagnostic models for laryngoscopy can reduce potential repeated biopsies and lessen the patient burden, representing an urgent clinical need. However, existing artificial intelligence models often function as black boxes and are trained on single, pre-selected images, which does not reflect the clinical workflow where multiple images are assessed. METHODS: We conducted a retrospective study on 611 patients who underwent white light endoscopy (WLE) examinations. We developed an interpretable multi-instance learning network (IMIL-Net), which uses a patient-level of images. The model uses a Swin Transformer encoder and a gated attention pooling mechanism to produce a patient-level diagnosis and instance-level interpretability scores. We evaluated the model using a 5-fold cross-validation and compared it against four baseline models. We quantitatively validated the model's interpretability by comparing its attention scores against physician-annotated regions of interest (ROI) from 30 cases using the Mann-Whitney U test. RESULTS: IMIL-Net achieved the highest diagnostic performance, with a mean area under the curve (AUC) of 0.975 (95% CI 0.959-0.991), accuracy of 0.915 (95% CI 0.883-0.947), sensitivity of 0.876 (95% CI 0.803-0.949), and specificity of 0.945 (95% CI 0.910-0.980). This was superior to all baseline models, including non-MIL architectures (AUC 0.888-0.897) and a logistic regression model using only clinical data (AUC 0.898). The model's interpretability was quantitatively confirmed: physician-annotated ROI images (n=63) received a significantly higher median attention score (20.94%) compared to non-ROI images (n=78, 15.32%,). CONCLUSION: The proposed IMIL-Net provides a high-accuracy, interpretable, and clinically-aligned diagnostic solution. By analyzing complete patient examinations and providing a statistically validated decision-making process, this model represents a trustworthy tool for integration into the clinical otolaryngology workflow.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Image-Based Diagnosis of Oral Lesions: Performance of a Vision-Language Model versus Human Clinicians.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026
- Multiple-InstanceLearning in Medical Imaging: Correlated Chained Gaussian Processes with a Weighted Noisy-OR LikelihoodMachine Learning and Knowledge Extraction · 2026
- Attention-based multiple-instance learning enables whole-slide pathology classification of esophageal squamous cell carcinoma versus esophageal adenocarcinoma with quantitative explainability.Diagnostic pathology · 2026
- Beyond attention heatmaps: How to get better explanations for multiple instance learning models in histopathologyMedical Image Analysis · 2026
- Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study.JMIR medical informatics · 2026
- nnMIL: a generalizable multiple instance learning framework for computational pathology.Nature biomedical engineering · 2026