Journal of imaging informatics in medicine

Resolution-Aware Cross-Modality Evaluation of CFP-Pretrained Retinal Vision-Language Models for Ultra-Widefield Diabetic Retinopathy Grading.

Siyun Lee, Baek Hwan Cho, Jihyeon Son, Yujin Nam, Junhyung Moon, Joonhyung Kim

Department of Ophthalmology, CHA University Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea. · Department of AI Healthcare Convergence, CHA University, Pocheon, Republic of Korea.

Observational · n=120

Key points

From the paper's conclusion
  • We hypothesized that direct zero-shot transfer to ultra-widefield (UWF) photographs would produce class-specific failure and assessed whether linear probing showed broader five-grade diabetic retinopathy (DR) separation in a held-out set.

Abstract

Retinal vision-language models (VLMs) pretrained on conventional color fundus photography (CFP) may be applied to other imaging systems without adequate modality-specific validation. We hypothesized that direct zero-shot transfer to ultra-widefield (UWF) photographs would produce class-specific failure and assessed whether linear probing showed broader five-grade diabetic retinopathy (DR) separation in a held-out set. In this retrospective single-center study, 300 de-identified UWF images from 120 eyes of 61 patients with diabetes were graded as no DR, mild, moderate, or severe nonproliferative DR, or proliferative DR. FLAIR and CLIP-DR were assessed at 512 × 512, 768 × 768, and 1024 × 1024 pixels. Both strategies were evaluated on the same 151-image test set from 24 patients; linear probes were fitted using a separate 149-image training set from 37 patients. Balanced accuracy, macro-F1, and macro-area under the receiver operating characteristic curve (macro-AUROC) were reported for both models. Class-specific and ordinal-error measures were also reported. CLIP-DR linear probing achieved macro-F1 of 0.365 at 1024 × 1024, compared with 0.254 for zero-shot inference. FLAIR zero-shot failed to identify severe nonproliferative DR at every resolution. FLAIR linear-probing macro-F1 peaked at 0.338 at 768 × 768 and decreased to 0.295 at 1024 × 1024; moderate- and severe-stage recall remained low. Direct CFP-to-UWF reuse therefore produced marked class collapse. Linear probing yielded higher macro-F1 estimates, but patient-cluster bootstrap intervals for all four primary contrasts included zero. Increasing resolution did not consistently improve performance. Modality-specific, class-resolved validation is required before retinal VLMs are reused across fundus imaging systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Resolution-Aware Cross-Modality Evaluation of CFP-Pretrained Retinal Vision-Language Models for Ultra-Widefield Diabetic Retinopathy Grading — Science Skim