Department of Pathology, Hospital Universitari de Vic, Consorci Hospitalari de Vic (C-17 Health Network), Vic, Barcelona, Spain. Electronic address: dbadia@chv.cat. · Faculty of Science, Technology and Engineering, Universitat de Vic - Universitat Central de Catalunya (UVic-UCC), Vic, Barcelona, Spain.

Computational · n=43

Key points

From the paper's conclusion
  • Guided by the pathologist, a locally deployed, general-purpose VLM achieved substantial categorical agreement with an expert pathologist. Its errors were systematic and unidirectional: manageable by protocol, but not harmless. Potential applications should be limited to pre-screening, prioritisation and quality control under supervision. The numerical output should not be reported and external validation is required.

Abstract

AIMS: The programmed death-ligand 1 (PD-L1) tumour proportion score (TPS) guides eligibility for first-line immunotherapy in non-small cell lung cancer (NSCLC), but its assessment relies on visual interpretation, and commercial digital tools can be costly. We evaluated whether a locally deployed, open-weight vision-language model (VLM) could support PD-L1 assessment in a community pathology department. METHODS: This concordance study included 43 consecutive cases of NSCLC with in-house PD-L1 22C3 staining. Pathologist-delineated regions of interest within whole-slide images were assessed independently by an expert pathologist (reference standard), a trained biomedical student and a locally deployed, open-weight, general-purpose VLM. The workflow was hybrid: the model did not analyse whole-slide images directly. No fine-tuning was performed; task specialisation relied on a single prompt. Agreement was assessed using Cohen's κ, quadratic-weighted κ, binary κ at the 1% and 50% cut-offs, and Bland-Altman analysis. RESULTS: Agreement between the student and expert pathologist was almost perfect (κ = 0.96). The model produced an evaluable result in 38 of 43 cases (88.4%); the remaining five were non-evaluable because of image blur. VLM-expert agreement was substantial (76.3%; κ = 0.65; quadratic-weighted κ = 0.80). At the 50% cut-off, agreement was 89.5% (κ = 0.78; sensitivity, 75.0%; specificity, 100%). All nine discordant assessments fell within the intermediate 1-49% TPS category, with no errors spanning two categories. Numerical TPS estimates were strongly correlated with the reference values (r = 0.83) but showed systematic underestimation (bias, -8.5 points). CONCLUSIONS: Guided by the pathologist, a locally deployed, general-purpose VLM achieved substantial categorical agreement with an expert pathologist. Its errors were systematic and unidirectional: manageable by protocol, but not harmless. Potential applications should be limited to pre-screening, prioritisation and quality control under supervision. The numerical output should not be reported and external validation is required.

Read the paper