Effectiveness and Safety of Tasso+ Pediatric Microsampling for Child Blood Lead Levels: Cohort Study.
Alana M W LeBron, Kristina Uban, Julia Mangione, Olaya Daki, Erika Ramirez-Mayoral, Maya Cheav, Sarahi Gutierrez Luna, Adriana Orellana,
Department of Health, Society, and Behavior, Joe C. Wen School of Population & Public Health, University of California, Irvine, 856 Health Sciences Quad, Office 3555, Irvine, CA, 92697, United States, 1 949-824-5242, 1 949-824-1019. · Community Member At-Large, Santa Ana, CA, United States.
Key points
From the paper's conclusion- These effectiveness barriers and adverse events highlight the need for documentation to inform the future rollout of novel devices for participatory research, longer-term follow-up, and addressing potential gaps in transparency between manufacturers and researchers who use biomedical devices.
Abstract
BACKGROUND: The growing interest in promoting child health requires minimally invasive biospecimen collection. Particularly during and since the COVID-19 pandemic, there has been increased interest in microsampling technology to democratize participation in research involving biospecimens, particularly for children. These advances mitigate barriers, such as scheduling, transportation, and psychosocial challenges. Tasso is a microsampling biomedical device that has gained popularity in research. It uses a vacuum-assisted capillary system that attaches to the upper arm and is considered minimally invasive, as it requires no venipuncture or phlebotomist. Yet, important gaps remain in understanding Tasso performance, particularly among pediatric populations where its administration is limited. OBJECTIVE: This research addresses a significant gap in biomedical device development by examining the effectiveness, safety, and failure rate of the Tasso+ Class II medical device designed for blood sampling (puncture) among children. The Tasso+ was selected for a pediatric cohort research study given advertisement of methodological advantages over traditional phlebotomy. This original investigation characterizes the effectiveness of and potential for institutional review board-designated adverse events, following the use of the Tasso+ Class II medical device within a pediatric population. METHODS: Blood collection was essential to measure lead (Pb) exposures for children residing in a region known to be polluted. Parents/guardians consented, and children assented to Tasso+ sampling on the upper arm. The Tasso+ device was administered in 2024 by trained researchers on 2 pilot participants (ages 7-8 years) and subsequently 13 study participants (ages 7-10 years). Sampling was terminated upon participant reports of persistent pain and scarring on children's arms. Follow-up was conducted at intervals after device application: 2-11 weeks and 10-19 months. Data sources included data collection and laboratory records and survey-based follow-up with participating families. Analyses involved descriptive statistics drawn from data collection and laboratory records and descriptive statistics and content analysis of a follow-up survey administered to participating families. Content analysis of open-ended responses to the follow-up survey administered to families identified themes and their frequency of occurrence. Main measures included the device failure rate, effectiveness (ie, blood volume), and adverse outcomes at the arm puncture site. RESULTS: The device failure rate was 26.7% (4/15), with only 66.7% (10/15) and 20% (3/20) of the cases having the optimal (>450 µL) or adequate (250-449 µL) blood volume, respectively. At initial follow-up, 23.1% reported ongoing pain; none reported ongoing pain at extended follow-up. Scarring showed high initial incidence (61.5%) and persistence (75.0%). Children reported shame related to the participant-reported and researcher-observed scar and impacts of pain on feelings toward physical touch (eg, hug/embrace). CONCLUSIONS: These effectiveness barriers and adverse events highlight the need for documentation to inform the future rollout of novel devices for participatory research, longer-term follow-up, and addressing potential gaps in transparency between manufacturers and researchers who use biomedical devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Application of the Volumetric Absorptive Micro Sampling Strategy to Quantify Dexmedetomidine in Capillary Blood Using an LC-MS/MS Method.Journal of clinical laboratory analysis · 2026
- A-390 Method comparison of a novel capillary blood collection device for clinical chemistry testing: comparison with venous blood on two automated platformsClinical Chemistry · 2026
- A-389 Understanding sample-to-sample variability in capillary blood collections: comparison with venous samplingClinical Chemistry · 2026
- Advancing neonatal care through non-invasive biochemical monitoring and diagnostics.Biosensors & bioelectronics · 2026
- Capillary Blood Collection Methods: An assessment of different collections technologies compared to traditional venous sampling.Annals of clinical biochemistry · 2026
- Blood sampling for research purposes in children: a practical guide to volume limits and minimisation strategies.European journal of pediatrics · 2026