Biosensors & bioelectronics

Advancing neonatal care through non-invasive biochemical monitoring and diagnostics.

Hanbyeol Son, Doyoun Kim, W Hong Yeo, Hyo-Ryoung Lim

Major of Human Bioconvergence, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan, Republic of Korea. · George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA; Wearable Intelligent Systems and Healthcare Center (WISH Center) at the Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, USA; Wallace H. Coulter Department of Biomedical Engineering, Georgia Tech and Emory University School of Medicine, Atlanta, GA, USA; Parker H. Petit Institute for Bioengineering and Biosciences, Georgia Institute of Technology, Atlanta, GA, USA. Electronic address: whyeo@gatech.edu.

Review

Key points

From the paper's conclusion
  • Adapting established test-evaluation methodology, we define the evidence required for replacement, triage, add-on, monitoring, discovery, and diagnosis with matrix-native thresholds, and we add requirements specific to non-invasive matrices: sampling failure, variable matrix-to-blood ratios, and matrix confounders.

Abstract

Repeated blood sampling remains the basis of neonatal biochemical assessment, although it is painful and, in extremely preterm infants, removes close to one third of the circulating blood volume. Non-invasive biosensing offers alternatives, but most studies report analytical figures of merit or correlation with blood, which do not show whether a measurement meets the requirements of clinical use. This review maps neonatal biomarkers to saliva, sweat, tears, urine, and exhaled breath and to electrochemical, optical, and chemiresistive platforms, and compares their technical progress with the requirements of clinical use. Adapting established test-evaluation methodology, we define the evidence required for replacement, triage, add-on, monitoring, discovery, and diagnosis with matrix-native thresholds, and we add requirements specific to non-invasive matrices: sampling failure, variable matrix-to-blood ratios, and matrix confounders. Neonatal data show that the same statistic can lead to opposite conclusions, as salivary caffeine and C-reactive protein illustrate. Only sweat chloride and transcutaneous bilirubin are established in routine neonatal practice. Among representative custom-engineered devices, the evidence mostly stops at paired comparison in selected, case-control, or balanced samples, and performance in consecutively enrolled infants is rarely reported. For small molecules and electrolytes, progress now depends more on study design, namely consecutive enrollment and paired sampling at clinically indicated blood draws, than on further gains in analytical sensitivity. Extending the framework to early-life protection, we argue that a measurement protects an infant only when it detects change in time for an effective intervention, and that this chain is so far best supported within established screening pathways.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Advancing neonatal care through non-invasive biochemical monitoring and diagnostics — Science Skim