Biomechanical assessment of titanium, zirconia, and polyetheretherketone abutments under functional loads: A finite element study.
Khaled Omran Ben Khalil, Simge Dagistan, Sinan Köse, Gülhan Yıldırım
Department of Orthodontics, Faculty of Dentistry, Cyprus Health and Social Sciences University, Guzelyurt, North Cyprus. · Department of Prosthodontics, Faculty of Dentistry, Bahçeşehir University, Istanbul, Turkey.
Key points
From the paper's conclusion- Abutment material was found to play a critical role in the biomechanical performance of implant-supported restorations, affecting stress distribution within the implant system under functional loading.
Abstract
PURPOSE: To compare the biomechanical behavior of titanium, zirconia, and polyetheretherketone (PEEK) abutments in implant-supported restorations under vertical and oblique loading using finite element analysis. METHODS: Three three-dimensional models were created using SolidWorks software and analyzed using finite element software (version 11.0, Swanson Analysis, Inc., Houston, USA). Each model included a titanium implant (4.3 × 13 mm) connected to abutments made of titanium, zirconia, or PEEK. A metal-ceramic crown was designed for each case. All materials were modeled as isotropic, linearly elastic, and homogeneous. A static load of 300 N was applied either vertically or obliquely at a 45° angle. Von Mises stresses and displacements were evaluated for implant components, and principal stress analysis was performed for peripheral bone and abutments. RESULTS: Stress values varied according to abutment material and loading direction. Stress concentrations were primarily located at the implant neck and gingival region of the abutments. PEEK generated the highest implant stress under both vertical (208.27 MPa) and oblique (742.21 MPa) loading. Abutment stress peaked in the zirconia group, reaching 229.41 MPa under vertical and 912.43 MPa under oblique loading. The highest screw stress was recorded in the titanium abutment group under oblique force (388.98 MPa). CONCLUSIONS: Abutment material was found to play a critical role in the biomechanical performance of implant-supported restorations, affecting stress distribution within the implant system under functional loading.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Connection Geometry and Cantilever Length on the Mechanical Behavior of Ti6Al4V and PEEK Bar-Supported Implant Prostheses with Angled Abutments.Journal of functional biomaterials · 2026
- Biomechanical Implications of Abutment Geometry Modification in Polymer‐Based Dental Implant SystemsEngineering Reports · 2026
- Effect of distal cantilever and anterior implant diameter on framework and cortical bone stress in a PEEK-based All-on-Four mandibular prosthesisFrontiers in Dental Medicine · 2026
- Stress Evaluation of Indirect Composite Superstructure on Different Copings in CAD-on Technique for Restoration of Titanium Dental Implants—3D Finite Element AnalysisEuropean Journal of General Dentistry · 2026
- Finite Element Analysis of Stress Distribution in Healthy and Restored Mandibular Molars with Zirconia and Lithium Disilicate Crowns Under Vertical and Oblique Loading.Journal of functional biomaterials · 2026
- PEEK plates for the fixation of mandibular condylar base fractures: a finite element analysis comparison of single and double plate configurations with titanium and resorbable systems.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026