Biomechanical Implications of Abutment Geometry Modification in Polymer‐Based Dental Implant Systems
Shuaib Al Rashid, M. S. Rabbi
Key points
From the paper's conclusion- Overall, the results indicate that geometric modification can improve the mechanical response and load‐bearing capability of polymer‐based abutments without substantially affecting their deformation characteristics.
Abstract
Polymer‐based dental implant abutments offer potential advantages over conventional metallic materials but their mechanical performance is strongly influenced by material and geometric design. This study evaluates three polymeric abutment materials, PEKK, 30 wt% GFR‐PEEK and 30 wt% CFR‐PEEK, using finite element analysis under a 100 N static oblique occlusal load applied at 30° to the implant longitudinal axis. Standard and modified abutment geometries were evaluated based on equivalent stress, total deformation, equivalent elastic strain, strain energy and predicted yield load. The modified geometry reduced the maximum equivalent stress by up to 20.49% and strain energy by up to 12.59%, while increasing the predicted yield load by up to 25.74%. The highest predicted yield load was obtained with modified CFR‐PEEK at 235.2 N, compared with 187.2 N for its standard geometry. Total deformation showed only minor changes across the investigated cases. Overall, the results indicate that geometric modification can improve the mechanical response and load‐bearing capability of polymer‐based abutments without substantially affecting their deformation characteristics. Among the investigated materials, CFR‐PEEK demonstrated the highest predicted load‐bearing capacity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Connection Geometry and Cantilever Length on the Mechanical Behavior of Ti6Al4V and PEEK Bar-Supported Implant Prostheses with Angled Abutments.Journal of functional biomaterials · 2026
- Biomechanical assessment of titanium, zirconia, and polyetheretherketone abutments under functional loads: A finite element study.Journal of prosthodontic research · 2026
- Stress Evaluation of Indirect Composite Superstructure on Different Copings in CAD-on Technique for Restoration of Titanium Dental Implants—3D Finite Element AnalysisEuropean Journal of General Dentistry · 2026
- Effect of distal cantilever and anterior implant diameter on framework and cortical bone stress in a PEEK-based All-on-Four mandibular prosthesisFrontiers in Dental Medicine · 2026
- PEEK plates for the fixation of mandibular condylar base fractures: a finite element analysis comparison of single and double plate configurations with titanium and resorbable systems.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026
- Overcoming the Biomechanical Limitations of Titanium-Zirconia Dental Implants: Rationale for a Novel Ti-PEEK-Zr Tri-Layered Concept.Journal of functional biomaterials · 2026