Stress Evaluation of Indirect Composite Superstructure on Different Copings in CAD-on Technique for Restoration of Titanium Dental Implants—3D Finite Element Analysis
Sahithi Bandi, Kiran Kumar Pandurangan, Subhabrata Maiti, Delphine Priscilla Antony, Mario Alberto Alarcón‐Sánchez, Artak Heboyan, Gustavo Eder González-Alvarez, Sarah Monserrat Lomelí-Martínez
Saveetha University · Universidad de Guadalajara
Key points
From the paper's conclusion- These findings suggest that flexible polymeric copings provide more biomechanically favorable load transfer, supporting their use as resilient alternatives for implant-supported prostheses.
Abstract
Abstract The aim of the study is to evaluate and compare the stress distribution and total deformation of indirect composite veneered superstructures fabricated using different coping materials—zirconia, biocompatible high-performance polymer (BioHPP), and polyetherketoneketone (PEKK)—via the CAD-on technique using three-dimensional (3D) finite element analysis. A 3D finite element model of a mandibular second premolar restored with a 4.1 × 12 mm titanium implant and internal hex abutment was digitally reconstructed. Four restorative configurations were analyzed: (G1) zirconia coping with hand-layered ceramic veneer, (G2) zirconia coping with HIPC veneer, (G3) BioHPP coping with HIPC veneer, and (G4) PEKK coping with HIPC veneer. Models were developed in ANSYS Workbench 2022 R2 and subjected to a static vertical load of 280 N applied over the occlusal surface. Von Mises stress and total deformation were measured at the coping, abutment, and implant interfaces. Data were analyzed using one-way ANOVA (Analysis of Variance) and Tukey's post-hoc test (α = 0.05). The highest stress occurred in G1 (29.62 ± 37.73 MPa) at the implant margin, while the lowest values were noted in G3 (13.05 ± 9.63 MPa at the coping; 14.13 ± 2.06 MPa at the abutment). Total deformation differed significantly among groups (p <0.05), with G4 showing the least deformation (0.78 ± 0.02 mm) at coping level and G3 demonstrating minimal deformation at the implant abutment (0.78 ± 0.02 mm). Polymer-based CAD-on restorations, especially BioHPP and PEKK copings veneered with HIPC, exhibited superior stress modulation and lower deformation compared to zirconia-based systems. These findings suggest that flexible polymeric copings provide more biomechanically favorable load transfer, supporting their use as resilient alternatives for implant-supported prostheses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical assessment of titanium, zirconia, and polyetheretherketone abutments under functional loads: A finite element study.Journal of prosthodontic research · 2026
- Biomechanical Implications of Abutment Geometry Modification in Polymer‐Based Dental Implant SystemsEngineering Reports · 2026
- Biomechanical Evaluation of CAD/CAM Restorative Materials for Maxillary Second Premolar Crowns Using Three-Dimensional Finite Element AnalysisProsthesis · 2026
- Quantifying Stress Shielding in Dental Implants: A Comparative Finite Element Study of Titanium, CFR-PEEK, and Ceramic MaterialsMaterials · 2026
- Finite element analysis of stress distribution in zygomatic implant configurations with different hybrid prosthesis superstructure materialsScientific Reports · 2026
- Mechanical behavior of complete arch implant-supported prostheses with distal cantilevers fabricated from different digital material combinationsJournal of Prosthetic Dentistry · 2026