Diagnosing lung cancer invading the pulmonary artery using ultra-low-dose CT pulmonary angiography: a feasibility study.
Jiandong Guo, Xuelin Zhang, Yongyi Li, Xiongfei Chen, Huirong Su, Yue Zhou, Yongjun Zhang, Jianjun Shen,
Department of Radiology, Shenzhen Hospital (Futian) of Guangzhou University of Chinese Medicine, Shenzhen, China. · United Imaging Healthcare, Shanghai, China.
Key points
From the paper's conclusion- A 60-kVp triple-low CTPA protocol achieved ~80% dose reduction while maintaining image quality and diagnostic accuracy for evaluating PAI, supporting clinical implementation.
Abstract
BACKGROUND: Computed tomography pulmonary angiography (CTPA) is widely used for evaluating pulmonary artery invasion (PAI) in lung cancer, but conventional protocols involve relatively high radiation dose and contrast medium usage. The feasibility of a 60-kVp "triple-low" protocol combining low tube voltage, reduced contrast volume, and reduced injection rate in preserving image quality and diagnostic performance remains to be determined. Therefore, this study aimed to evaluate the feasibility of a 60-kVp "triple-low" CTPA protocol for assessing pulmonary artery invasion in patients with lung cancer. METHODS: In this prospective randomized study, 90 patients were assigned to routine dose (RD) CTPA (120 kVp, 50 mL, 4.5 mL/s; n=45) or ultra-low-dose (ULD) CTPA (60 kVp, 35 mL, 3.5 mL/s; n=45). Two senior thoracic radiologists established the reference standard by consensus after reviewing available pathological, imaging, and clinical records. Subjective image quality was evaluated using a 5-point Likert scale across multiple parameters, including enhancement homogeneity and vascular sharpness. Radiation dose was recorded, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured at the main, right, and left pulmonary arteries. Two additional readers independently assessed PAI; receiver operating characteristic (ROC) analysis against the reference standard yielded the area under the ROC curve (AUC), sensitivity, specificity, and accuracy. RESULTS: ULD reduced effective dose (ED) from 3.59 to 0.72 mSv (~80%). Subjective scores were comparable between protocols for enhancement homogeneity, vascular sharpness, and diagnostic confidence (all P>0.05). SNR and CNR were similar overall, with a small decrease at the left pulmonary artery in the ULD group. Diagnostic performance for PAI was comparable between ULD and RD for both readers (reader 1: AUC 0.936 vs. 0.940; reader 2: 0.936 vs. 0.925; both P>0.05). CONCLUSIONS: A 60-kVp triple-low CTPA protocol achieved ~80% dose reduction while maintaining image quality and diagnostic accuracy for evaluating PAI, supporting clinical implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Image quality and radiation dose optimization in CT pulmonary angiography using 120, 100, and 80 kV protocols for pulmonary thromboembolism diagnosis.Quantitative imaging in medicine and surgery · 2026
- Feasibility of deep learning reconstruction algorithm combined with the "ultra triple-low" protocol at 60 kVp in CTPA: An image quality and radiation dose assessment.European journal of radiology · 2026
- Quantitative and qualitative lung parameters in photon-counting CT: comparison of ultra-low-dose with standard low-dose protocols.European radiology · 2026
- Application of 50-keV virtual monochromatic imaging combined with a personalized contrast agent protocol in computed tomography pulmonary angiography: a randomized controlled trial.Quantitative imaging in medicine and surgery · 2026
- Reducing contrast media dosage for pulmonary embolism CTPA in PCD-CT: a comparative study of EID-CT and PCD-CT in the era of individualized protocollingEuropean Radiology · 2025
- Diagnostic Feasibility and Physical Assessment of Lung CT Images Reconstructed From Ultra-Low-Dose Positioning Scan for Computer-Aided Nodule Detection.Journal of computer assisted tomography · 2026