Reducing contrast media dosage for pulmonary embolism CTPA in PCD-CT: a comparative study of EID-CT and PCD-CT in the era of individualized protocolling
Lion Stammen, Eva J I Hoeijmakers, Thomas Flohr, Hester A. Gietema, Janneke Vandewall, Joachim E. Wildberger, Cécile R. L. P. N. Jeukens, Bibi Martens
Maastricht University Medical Centre
Key points
From the paper's conclusion- To evaluate diagnostic image quality (IQ) for pulmonary embolism detection in photon-counting detector CT (PCD-CT) with significantly reduced contrast media (CM) dose vs conventional energy-integrating detector CT (EID-CT), using optimized and individualized CM protocols.
Abstract
OBJECTIVES: To evaluate diagnostic image quality (IQ) for pulmonary embolism detection in photon-counting detector CT (PCD-CT) with significantly reduced contrast media (CM) dose vs conventional energy-integrating detector CT (EID-CT), using optimized and individualized CM protocols. MATERIALS AND METHODS: Consecutive CT pulmonary angiography (CTPA) scans performed on the EID-CT (Jan 2024-Mar 2024) with an individualized kilovoltage (kV) and total body weight (TBW) adapted CM protocol, and on the PCD-CT (Aug 2023-Feb 2024) with a TBW adapted CM protocol matching the 70 kV EID-CT protocol, were retrospectively collected. EID-CT scans were performed at 70-120 kV, based on patients' size, while PCD-CT scans were performed at 120 kV with 55 keV virtual monoenergetic images. Objective IQ assessment included mean attenuation (in Hounsfield Units), signal-to-noise ratio, and contrast-to-noise ratio (CNR). Two board-certified radiologists assessed diagnostic IQ subjectively using a five-point Likert scale. RESULTS: In 140 EID-CT and 118 PCD-CT scans, PCD-CT reduced total iodine load by 26.7% and CT dose index volume by 24.4%. Objective IQ parameters showed no significant differences, except for a decrease in CNR in the proximal pulmonary arteries in PCD-CT scans (p = 0.02). Subjective IQ was rated as moderate/good by observers 1 and 2 in 94.9% and 97.9% of the EID-CT scans, respectively, and 96.5% and 100% of the PCD-CT scans, respectively. CONCLUSION: PCD-CT with a TBW-adapted CM protocol can achieve substantial reductions in both CM and radiation dose compared to EID-CT with individualized kV and TBW adapted CM protocols, while maintaining diagnostic IQ in CTPA scans. KEY POINTS: Question The feasibility of CM reduction in PCD-CT vs EID-CT with highly individualized CM protocols, while maintaining diagnostic IQ. Findings PCD-CT reduces total iodine load by 26.7% and CT dose index volume by 24.4% compared to EID-CT, with comparable objective and subjective diagnostic IQ. Clinical relevance This approach enables CM reduction, potentially lowering patient risk and providing environmental and financial benefits. Additionally, PCD-CT allows for CM and radiation dose reduction while maintaining comparable IQ.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Photon-counting detector CT for CT pulmonary angiography: a systematic review and meta-analysis.European radiology · 2026
- Pulmonary Artery CT Angiography on Photon-Counting Detector CT: A Practical One-Stop Acquisition, Reconstruction, and Reporting Protocol.Tomography (Ann Arbor, Mich.) · 2026
- Image quality and radiation dose optimization in CT pulmonary angiography using 120, 100, and 80 kV protocols for pulmonary thromboembolism diagnosis.Quantitative imaging in medicine and surgery · 2026
- Pulmonary Iodine Map Defects Across Contrast Phases in Routine Photon-Counting Detector CT: An Exploratory Study.Diagnostics (Basel, Switzerland) · 2026
- Application of 50-keV virtual monochromatic imaging combined with a personalized contrast agent protocol in computed tomography pulmonary angiography: a randomized controlled trial.Quantitative imaging in medicine and surgery · 2026
- Photon-Counting CT Enables Higher Image Quality at a Lower Radiation Dose Compared with a 256-Slice Energy-Integrating Detector CT in Pediatric Patients with Congenital Heart DiseaseDiagnostics · 2026