Calibration of a fully closed-loop lumped-parameter cardiovascular model with baroreflex in response to induced central hypovolemia.
Karolina Tlałka, Harry Saxton, Ian Halliday, Xu Xu, Andrew Narracott, Daniel James Taylor, Lars Øivind Høiseth, Jonny Hisdal,
Division of Clinical Medicine, School of Medicine and Population Health, University of Sheffield, Sheffield, United Kingdom. · Astellas Pharma Europe Ltd, Addlestone, England.
Key points
From the paper's conclusion- We perform global sensitivity analysis and orthogonality analysis of a 58-parameter non-linear cardiovascular model including the baroreflex, to select an optimal subset of parameters for model calibration.
Abstract
Calibration of cardiovascular models is essential to their clinical utility. We provide a full description of the calibration of a non-linear, dynamic model using global optimisation methods. Specifically, we consider an experimental cohort response in a closed-loop, baro-regulated cardiovascular model, in the setting of induced central hypovolemia.We propose a framework for simplifying calibration of dynamic, regulated models. We perform global sensitivity analysis and orthogonality analysis of a 58-parameter non-linear cardiovascular model including the baroreflex, to select an optimal subset of parameters for model calibration. We fit the model to relative Lower Body Negative Pressure data, using global optimisation (Differential Evolution method), searching a reduced input parameter space. Global sensitivity analysis and orthogonality analysis revealed multiple higher-order interactions within the model, as well as areas of similar influence of input parameters, on the components of the objective function. The model was fitted using only baroreflex parameters. Relative errors in the estimation of heart rate, mean arterial pressure, and stroke volume were reduced from -15.03%, 1.60% and 42.06% before calibration to 0.42%, -1.37% and 0.61% after the fitting, respectively.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Representing Sex in Cardiovascular Models: Calibrating Reference Parameters from Healthy CohortsbioRxiv · 2026
- A physiologically constrained calibration framework for cardiovascular models applied to a paediatric synthetic sepsis population.PLoS computational biology · 2026
- Cardiovascular digital twin personalization using arterial blood pressure-driven optimization of a Windkessel-baroreflex model.Biomedical engineering letters · 2026
- OpenCRS: an open-source regulated human cardiorespiratory model with large-scale calibration and global sensitivity analysis at rest and during exercisebioRxiv · 2026
- A Calibration Framework for Patient-Specific 1D Arterial Models: Reflection-Coefficient Pre-Optimization, Coupled Conduit-Peripheral Compliance, and Exact Terminal Flow Distribution.International journal for numerical methods in biomedical engineering · 2026
- Evolutionary Optimization of Extended Kalman Filter Hyperparameters for Adaptive Data-Driven ABP Prediction Framework Inspired by Cardiovascular Digital-Twin PrinciplesAlgorithms · 2026