Cardiovascular digital twin personalization using arterial blood pressure-driven optimization of a Windkessel-baroreflex model.
Rahmafatin Nurul Izza, Frederique Jos Vanheusden, Fauzan Syarif Nursyafi, Ki Moo Lim
Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi, North Gyeongsang 39177 Republic of Korea. · Department of Engineering, School of Science and Technology, Nottingham Trent University, New Hall Block, Room 177, Clifton Campus, Clifton Lane, Nottingham, NG11 8NS UK.
Key points
From the paper's conclusion- This study presents a cardiovascular digital twin personalization framework that integrates circulation system hemodynamic parameter optimization with arterial baroreflex gain calibration using only non-invasive arterial blood pressure measurements.
Abstract
UNLABELLED: Cardiovascular digital twins have emerged as powerful tools for modeling patient-specific cardiovascular physiology and supporting clinical decision-making. However, their practical adoption remains limited due to reliance on invasive or imaging-based data and computationally intensive personalization procedures. This study presents a cardiovascular digital twin personalization framework that integrates circulation system hemodynamic parameter optimization with arterial baroreflex gain calibration using only non-invasive arterial blood pressure measurements. A twelve-compartment Windkessel-baroreflex model was personalized in two steps. First, left ventricular end-systolic elastance and global vascular resistance and compliance scaling were optimized from a single resting arterial pressure waveform. After this, arterial baroreflex gains for total peripheral resistance and venous unstressed volume were tuned from beat-by-beat responses during head-up tilt and subject characteristics. In 10 PhysioNet subjects, the personalized models reproduced resting systolic, diastolic, and mean arterial pressures with absolute errors below 5 mmHg. The model also reproduced the main features of heart-rate and arterial-pressure responses during rapid and slow tilt, with better quantitative agreement for heart rate than for mean arterial pressure. These findings support the feasibility of constructing personalized cardiovascular digital twins from non-invasive arterial pressure recordings, while indicating the need for further refinement and broader validation before reliable subject-specific pressure prediction can be claimed. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at https://doi.org/10.1007/s13534-026-00584-x.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Calibration of a fully closed-loop lumped-parameter cardiovascular model with baroreflex in response to induced central hypovolemia.PloS one · 2026
- Cardiovascular digital twins using a Windkessel physics informed neural networknpj Digital Medicine · 2026
- A physics-informed peripheral hemodynamic digital twin for personalized estimation of arterial stiffnessnpj Digital Medicine · 2026
- A Real-Time Digital Twin for Human Cardiovascular Applications.International journal for numerical methods in biomedical engineering · 2026
- Evolutionary Optimization of Extended Kalman Filter Hyperparameters for Adaptive Data-Driven ABP Prediction Framework Inspired by Cardiovascular Digital-Twin PrinciplesAlgorithms · 2026
- A Calibration Framework for Patient-Specific 1D Arterial Models: Reflection-Coefficient Pre-Optimization, Coupled Conduit-Peripheral Compliance, and Exact Terminal Flow Distribution.International journal for numerical methods in biomedical engineering · 2026