A physiologically constrained calibration framework for cardiovascular models applied to a paediatric synthetic sepsis population.
Manuel T Cabeleira, Samiran Ray, Nicholas C Ovenden, Vanessa Díaz-Zuccarini
Department of Mechanical Engineering, University College London, London, United Kingdom. · Paediatric Intensive Care Unit, Great Ormond Street Hospital for Children NHS Foundation Trust, London, United Kingdom.
Key points
From the paper's conclusion- These results establish EFC as a general, scalable calibration strategy for mechanistic cardiovascular models and a practical foundation for virtual population generation and future patient-specific digital twin applications in critical care.
Abstract
Calibration of mechanistic cardiovascular models is a central barrier to their use in population analysis and patient-specific simulation, particularly in settings where key physiological variables are unobservable and multiple parameter combinations can reproduce the same haemodynamic targets. In this work, we present Embedded Feedback Controller (EFC), a calibration framework for ODE-based lumped-parameter cardiovascular models in which selected physiological parameters are promoted to dynamic states and driven toward prescribed targets through embedded controller equations. By exploiting the qualitative structure of the governing equations, EFC enforces physiologically consistent parameter-variable relationships and converges to the single solution admitted by an over-determined set of targets, reproducibly and independently of the initial conditions, at a cost that scales efficiently with model complexity. The framework is demonstrated in silico, using a mechanistic cardiovascular model to generate virtual paediatric populations spanning normal physiology and two septic shock phenotypes (warm and cold shock) from literature-derived target ranges, achieving <1% residual error across pressures, flows, and compartmental volumes. The resulting parameter distributions are consistent, by construction with theoretical haemodynamic adaptations in paediatric sepsis, including alterations in vascular resistance, compliance, cardiac elastance, and effective blood volume. Importantly, persistent calibration residuals arise when target combinations are structurally incompatible with the model and the parameter carrying the residual is held at a bound, providing an explicit and interpretable diagnostic of feasibility limits. These results establish EFC as a general, scalable calibration strategy for mechanistic cardiovascular models and a practical foundation for virtual population generation and future patient-specific digital twin applications in critical care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Calibration of a fully closed-loop lumped-parameter cardiovascular model with baroreflex in response to induced central hypovolemia.PloS one · 2026
- Representing Sex in Cardiovascular Models: Calibrating Reference Parameters from Healthy CohortsbioRxiv · 2026
- From Hemodynamics to Energetics: Parameter Identification in a Closed-Loop Model of the Cardiovascular System.International journal for numerical methods in biomedical engineering · 2026
- Evolutionary Optimization of Extended Kalman Filter Hyperparameters for Adaptive Data-Driven ABP Prediction Framework Inspired by Cardiovascular Digital-Twin PrinciplesAlgorithms · 2026
- A Subject-Specific Cerebrovascular CFD Modeling Approach Based on a Multimodal Data-Driven Boundary Calibration Framework: A Proof-of-Concept Study.Bioengineering (Basel, Switzerland) · 2026
- Cardiovascular digital twin personalization using arterial blood pressure-driven optimization of a Windkessel-baroreflex model.Biomedical engineering letters · 2026