A Calibration Framework for Patient-Specific 1D Arterial Models: Reflection-Coefficient Pre-Optimization, Coupled Conduit-Peripheral Compliance, and Exact Terminal Flow Distribution.
Javier Murillo, Juan Mairal, Luis Sánchez-Fuster, Javier Orera
I3A and Fluid Mechanics Department, University of Zaragoza, Zaragoza, Spain.
Key points
From the paper's conclusion- Overall, the method provides a versatile tool for developing reliable subject-specific models.
Abstract
The accurate simulation of blood pressure and flow waveforms in patient-specific 1D models requires precise calibration of numerous parameters, a task often complicated by limitations in clinical measurements and by heterogeneous modeling assumptions. This work proposes a comprehensive calibration methodology designed to ensure physiological consistency in the modeling of arterial networks across multiple spatial scales. The framework introduces a pre-optimization strategy based on reflection coefficients to balance potential mismatches between measured inflow conditions, network topology, and pulse wave velocity distributions by quantifying their impact on reflections at terminal-segment and junctions. A key component of the proposed approach is the combined calibration of conduit (1D) compliance and peripheral (0D) compliance, which are shown to be strongly coupled in realistic patient-specific geometries and therefore cannot always be tuned independently to match pulse-pressure targets. In parallel, we introduce a computational strategy to calibrate total and peripheral resistances so as to enforce an exact distribution of mean flow across all terminal segments while converging to target diastolic pressure. This exact enforcement of terminal flow fractions is vital to reliably compare and analyze the impact of alternative modeling hypotheses (friction/velocity-profile assumptions, local versus averaged impedance, and pulse wave velocity formulations) without confounding effects due to residual flow-distribution errors. The robustness of the proposed approach is demonstrated in four scenarios of increasing complexity, ranging from experimental hydraulic replicas to highly detailed systemic arterial trees. Overall, the method provides a versatile tool for developing reliable subject-specific models. It enables a systematic assessment of how different factors, such as vascular topology, the balance between central and peripheral compliance, and the control of wave reflections, directly influence the accuracy of hemodynamic predictions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cardiovascular digital twin personalization using arterial blood pressure-driven optimization of a Windkessel-baroreflex model.Biomedical engineering letters · 2026
- Personalized haemodynamic modelling for non-invasive quantification of arterial stiffness in the human vasculature.Journal of the Royal Society, Interface · 2026
- Calibration of a fully closed-loop lumped-parameter cardiovascular model with baroreflex in response to induced central hypovolemia.PloS one · 2026
- Pressure-Resolved Predicted Local Pulse Wave Velocity in the Human Abdominal Aorta: Association with Model-Derived Arterial Wall Mechanics.Journal of cardiovascular development and disease · 2026
- A 3D PINN-Based Framework for Patient-Specific Pulmonary Hemodynamics Using Windkessel ModelsarXiv · 2026
- Multi-scale 0D-1D, 0D-3D, 1D-3D coupling for cardiovascular simulation and modelling applications: A review.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026