Effective wavenumber coordinate correction and CO2 concentration retrieval constrained by an absorption-band prior.
Biming Mo, Songtao Gao, Jinzuo Zhou, Xiaojian Hao, Hong Jin
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, Taiyuan, Shanxi, China. haoxiaojian@nuc.edu.cn. · Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan, Shanxi, China. haoxiaojian@nuc.edu.cn.
Key points
From the paper's conclusion- Here, we report a joint inversion method for CO2 direct absorption spectroscopy, in which the molecular absorption-band structure is used as an internal spectral constraint for effective wavenumber coordinate correction and concentration retrieval.
Abstract
Molecular absorption spectroscopy provides a species-selective basis for quantitative gas sensing and compact optical diagnostics in combustion, industrial processes, and emission monitoring. However, in scanned semiconductor laser spectrometers operating without an online frequency reference, residual tuning nonlinearities introduce deviations in the wavenumber coordinate that affect spectral registration, baseline variation, and concentration retrieval. Here, we report a joint inversion method for CO2 direct absorption spectroscopy, in which the molecular absorption-band structure is used as an internal spectral constraint for effective wavenumber coordinate correction and concentration retrieval. Using the prior trajectory derived from the scan as the initial coordinate, the method estimates the residual wavenumber correction for each scan, a compact model of the non-absorbing intensity baseline, and the CO2 mole fraction within a unified forward model, without requiring an online Fabry-Perot etalon, reference absorption cell, or wavemeter. In experiments with a DFB laser operating near 4990 cm-1, a 45.0 cm effective path length, and standard CO2/N2 gas mixtures with concentrations ranging from 1000 to 4500 ppm, the absorption-band prior method reduced the absorbance residual RMSE from 2.01 × 10-3 to 9.60 × 10-4 compared with that of single-peak retrieval. For concentration retrieval, the mean absolute relative error and concentration standard deviation decreased from 4.08% to 1.63% and from 92.3 ppm to 38.9 ppm for single-scan retrieval and from 2.32% to 1.39% and from 60.8 ppm to 27.1 ppm after averaging over nine scan periods, respectively. These results show that spectroscopic constraints applied across the absorption band provide an effective approach for improving spectral registration, concentration accuracy, and retrieval stability over short measurement intervals in DAS systems operating without an online frequency reference.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cavity Ring-Down Spectroscopy at Benchmark-Level Sub-Permille Accuracy Enabled by a System-Level Detection Transfer FunctionarXiv · 2026
- Full-range CO2 detection using dual-path WMS-DAS and multi-regime adaptive fusion.Optics letters · 2026
- Improved precision of Raman-derived 13C/12C and 18O/16O in CO2 using bandwidth-fluctuation correction and optimized curve-fitting procedures.Applied optics · 2026
- Limits for molecular spectroscopy from quantum channel discriminationarXiv · 2026
- Double-resonance spectroscopy determines highly excited vibrational energy of 13CO2 with kilohertz accuracy.The Journal of chemical physics · 2026
- Physics-guided spectral attention for baseline-free concentration regression from laser absorption spectra.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026