Motion-corrected Gaussian, mean, and parametric curvature mapping of the posterior eye with pupil-tracked whole-eye OCT.
George Tian Funkenbusch, Rick Laoprasert, Nipun T Hewage, Arizona Greene, Joseph A Izatt, Anthony N Kuo, Ryan P McNabb
Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC 27708, USA. · Duke University School of Medicine, 40 Duke Medicine Circle, 124 Davison Building, Durham, NC 27710, USA.
Key points
From the paper's conclusion- We present a method utilizing 3D pupil tracking and sparse orthogonal scanning for post-acquisition correction of motion artifacts in posterior eye OCT volumes and their corresponding curvature maps.
Abstract
Optical coherence tomography (OCT) is a promising alternative to magnetic resonance imaging (MRI) for accessible, high-resolution measurement of posterior eye curvature, including for applications such as exploration of local eye shape deformations in pathologic myopia. However, OCT is a point-scanning interferometric imaging method that spatially encodes the effects of patient motion during acquisition into an acquired volume. These motion artifacts reduce accuracy and increase intra-acquisition variation in measured curvature, reducing the utility of OCT for monitoring posterior eye curvatures longitudinally. We present a method utilizing 3D pupil tracking and sparse orthogonal scanning for post-acquisition correction of motion artifacts in posterior eye OCT volumes and their corresponding curvature maps. We imaged six subjects exhibiting moderate (-6.0 to -3.0 D) to high (<-6.0 D) myopia and demonstrate a reduction in intra-session curvature variability when using our pupil tracking motion correction scheme. We also propose alternative metrics for representing 2-dimensional posterior eye curvature data to researchers and clinicians.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Uncertainty principle-guided intra-volume motion correction in full-field swept-source OCT for phase-stable retinal imaging.Optics express · 2026
- Spatially or temporally resolved phase-based optoretinography with actively tracked point-scanning optical coherence tomography.Optics letters · 2026
- Non-contact optical coherence elastography with motion-artifact correction and curvature compensation for quantitative assessment of in vivo keratoconus biomechanicsBiomedical Optics Express · 2026
- Phase-noise tolerant fully-coherent optical coherence tomography angiography for high-contrast 3D microvasculature mapping.bioRxiv : the preprint server for biology · 2026
- Intensity Variance-Guided Automated Robotic Optical Coherence Tomography System for Ophthalmic Applications.Journal of biophotonics · 2026
- Curvature-corrected retinal registration of diagnostic OCT with instrument-integrated OCTScientific Reports · 2025