Phase-noise tolerant fully-coherent optical coherence tomography angiography for high-contrast 3D microvasculature mapping.
Tianhui Jie, Sebastián Ruiz Lopera, Brett E Bouma, Néstor Uribe-Patarroyo
Key points
From the paper's conclusion- We also conducted an analysis of strategies for bias reduction in OCTA and developed the optimal method utilizing coherent spatiotemporal ensemble averaging.
Abstract
Optical coherence tomography angiography (OCTA) has been extensively explored for the detection of pathological retinal changes arising in various ophthalmological diseases. Due to phase instability of conventional systems, most OCTA signal processing methods to date have relied on intensity-based averaging, despite the resulting lower contrast and dynamic range compared to coherent averaging approaches. In this work, we (1) present a novel computation pipeline that enables fully-coherent processing in any phase-stable or phase-unstable system, and (2) demonstrate the first angiography metric with integrated signal-to-noise ratio (SNR) correction and coherent spatiotemporal ensemble averaging effective in any OCT system. Our method does not rely on 2D en face projections or binarization to produce high-contrast en face views and it significantly enhances the contrast-to-noise ratio of computed OCTA volumes, particularly in regions with reduced SNR levels. Our OCTA volumes also have high cross-sectional quality, enabling the use of single-depth en face views and the localization of capillary paths in the axial dimension. We can now identify capillaries below the retinal pigment epithelium, near the lamina cribrosa in the optic cup, which was not previously possible due to low SNR. We also conducted an analysis of strategies for bias reduction in OCTA and developed the optimal method utilizing coherent spatiotemporal ensemble averaging. Because our method leverages coherent averaging across all dimensions, it provides flexibility in shaping the averaging kernel to target specific workflows. The value of this additional degree of freedom is illustrated in our vessel tracing investigations, in which the depth resolution was maximized by limiting coherent ensemble averaging to the two lateral dimensions even in presence of strong phase noise, enabling the identification of 3D features such as overlapping capillary paths.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- OCT-guided angle-resolved low-coherence interferometry for microstructural analysis of the human retina.Biomedical optics express · 2026
- Spatially or temporally resolved phase-based optoretinography with actively tracked point-scanning optical coherence tomography.Optics letters · 2026
- Interscan time influence on effective in-vivo choriocapillaris imaging using a scanning distortion-corrected high-speed OCT system.Biomedical optics express · 2026
- Motion-corrected Gaussian, mean, and parametric curvature mapping of the posterior eye with pupil-tracked whole-eye OCT.Biomedical optics express · 2026
- Spatially-offset optical coherence tomography (SO-OCT) for high dynamic range biological imaging at depth.Biomedical optics express · 2026
- Automated anatomically guided quality assessment for OCTA via multi-region analysis and statistical calibrationBiomedical Optics Express · 2026