Curvature-corrected retinal registration of diagnostic OCT with instrument-integrated OCT
Marius Briel, Ludwig Haide, Michael Meyling, Benjamin Saalfrank, Philipp Matten, Nicola Piccinelli, Gernot Kronreif, Maria Francesca Spadea,
Carl Zeiss (Germany) · Karlsruhe Institute of Technology
Key points
From the paper's conclusion- This study introduces a novel technique for curvature-corrected retinal registration, integrating diagnostic OCT with instrument-integrated OCT.
Abstract
Vitreoretinal surgery, requiring precise microscale tissue manipulation, is well-suited for robotic assistance. Image registration enhances surgeons' visual perception by aligning high-resolution preoperative OCT images with the intraoperative environment, improving visibility of anatomical features not seen in microscope images. However, optical distortions from the cornea, lens, eye curvature, and scanning patterns challenge the use of diagnostic data in robotic navigation. This study introduces a novel technique for curvature-corrected retinal registration, integrating diagnostic OCT with instrument-integrated OCT. The pipeline comprises feature extraction, curvature correction, initial alignment, and fine registration. Experiments using an artificial model eye and ex vivo porcine eye validate the method. Curvature correction achieves accuracy comparable to existing methods, with deviations of 17 m for the model eye and 460 m for the porcine eye. Post-registration, the fiducial marker error reduces to 103 m for the model eye and 318 m for the porcine eye. Our method provides intraoperative diagnostic context, enabling reliable topological assistance in retinal robotic systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3D fast ray-traced distortion correction of indirectly viewed intraoperative retinal OCT for surgical tool path reconstruction.Biomedical optics express · 2026
- Motion-corrected Gaussian, mean, and parametric curvature mapping of the posterior eye with pupil-tracked whole-eye OCT.Biomedical optics express · 2026
- Distance-Based Shared Control for Vitreoretinal SurgeryIEEE Robotics and Automation Letters · 2025
- Intensity Variance-Guided Automated Robotic Optical Coherence Tomography System for Ophthalmic Applications.Journal of biophotonics · 2026
- Ronchi-calibrated bidirectional fast volume-repeat OCT for high-speed 4D imaging.Optics letters · 2026
- Motion Compensation and Adaptive Force Control via iOCT-FBG Sensor Fusion for Robotic Subretinal Injection.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation · 2026