Toward an optimized PET reconstruction protocol for spinal cord: superiority of OSEM with TOF and PSF.
Jiyuan Wang, Jing Huang, Bixiao Cui, Hongwei Yang, Defeng Tian, Jie Ma, Wanru Duan, Zan Chen,
Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, 100053, China. · Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China.
Key points
From the paper's conclusion- The OSEM + PSF + TOF reconstruction method demonstrated significant advantages in both image quality and quantitative assessment of FDG uptake, making it the recommended choice for spinal cord PET image reconstruction.
Abstract
BACKGROUND: Although multiple PET reconstruction approaches have been successfully applied in brain and oncologic imaging, their performance in the context of spinal cord imaging remains unverified. This study aims to identify the optimal reconstruction method for spinal cord PET image analysis based on assessments of image quality and quantitative uptake. METHODS: We retrospectively analyzed 18F-fluorodeoxyglucose (FDG) PET/MR data from 22 patients with cervical spinal cord tumors. PET images were reconstructed using Ordered Subset Expectation Maximization (OSEM), OSEM + Point Spread Function (PSF), OSEM + Time-of-Flight (TOF), and OSEM + TOF + PSF algorithms. Image quality was assessed by noise, signal-to-noise ratio (SNR), and signal-to-background ratio (SBR), both overall and within equally sized small (n = 11) and large (n = 11) tumor subgroups. Tumor uptake metrics, including SUVmean, SUVmax, SUVRmean, and SUVRmax of the lesions, were quantified for each method. The differences among reconstruction methods were assessed using the Friedman test. RESULTS: There were no significant differences in image noise among reconstruction methods (P > 0.05). Compared to OSEM reconstruction, the OSEM + PSF + TOF method significantly improved SNR (Z = 3.62, P < 0.01) and SBR (Z = 2.80, P = 0.03); the SBR of OSEM + PSF + TOF was also significantly higher than that of OSEM + PSF (Z = 3.04, P = 0.01). In large tumors, while image noise remained unaffected by the reconstruction method (P > 0.05), both SNR and SBR were significantly impacted (both P < 0.05). Specifically, OSEM + TOF + PSF achieved significantly higher SNR compared to OSEM (Z = 3.30, P < 0.01), and higher SBR compared to OSEM + PSF (Z = 3.14, P = 0.01). Quantitative lesion uptake metrics (SUVmax, SUVmean, SUVRmax, and SUVRmean) were significantly higher for OSEM + TOF + PSF compared to both OSEM and OSEM + PSF reconstructions (all P < 0.05). Additionally, SUVmean (Z = 2.92, P = 0.02) and SUVRmean (Z = 2.83, P = 0.03) values from OSEM + TOF + PSF reconstruction were significantly higher than those from OSEM + TOF. CONCLUSION: The OSEM + PSF + TOF reconstruction method demonstrated significant advantages in both image quality and quantitative assessment of FDG uptake, making it the recommended choice for spinal cord PET image reconstruction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Correlation of NEC to Image SNR and Lesion Detectability in clinical TOF PET.IEEE transactions on radiation and plasma medical sciences · 2026
- Proof-of-Concept Study of Task-Based Adaptive SPECT Imaging via System Sampling Strategies on a 12-Head Robotic SPECT Platform.IEEE transactions on medical imaging · 2026
- Characterization of open-source BSREM reconstruction for 123I-FP-CIT spect on a conventional anger-type SPECT/CT system: a phantom study.Physical and engineering sciences in medicine · 2026
- Attenuation Pre-Correction in Iterative PET Image Reconstruction: What is the Statistical Cost?IEEE transactions on radiation and plasma medical sciences · 2026
- Optimization of spectral photon-counting CT reconstruction parameters for improved detection of peritoneal metastases compared with energy-integrating detector dual-energy CT: a phantom study.European radiology experimental · 2026
- Reconstruction robustness of liver-referenced adaptive thresholding for 68Ga-PSMA-11 PET/CT volumetry: a comparative analysis of systematic bias and individual-patient variability.Annals of nuclear medicine · 2026