Reconstruction robustness of liver-referenced adaptive thresholding for 68Ga-PSMA-11 PET/CT volumetry: a comparative analysis of systematic bias and individual-patient variability.
Ellen Schötz, Dominic Ufton, Jasmin Weindler, Matthias Schmidt, Katrin S Roth, Alexander Drzezga, Carsten Kobe
Department of Nuclear Medicine, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany. · Department of Nuclear Medicine, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany. dominic.ufton@uk-koeln.de.
Key points
From the paper's conclusion- Reconstruction-dependent effects on PSMA-TV are strongly influenced by segmentation methodology. Liver-referenced adaptive thresholding minimized systematic reconstruction-related bias and demonstrated the highest robustness among evaluated approaches, although individual variability was not completely eliminated. Relative SUVmax-based segmentation showed substantially greater susceptibility to reconstruction changes. These findings support further evaluation of liver-referenced thresholding for standardized PSMA-TV assessment in longitudinal and multicenter settings.
Abstract
OBJECTIVE: PSMA tumor volume (PSMA-TV) is increasingly investigated as a quantitative biomarker for treatment assessment and prognostic stratification in metastatic castration-resistant prostate cancer (mCRPC). However, PSMA-TV depends on segmentation methodology and may be affected by reconstruction-related changes in PET image characteristics. This study evaluated the robustness of different PSMA-TV segmentation approaches across two reconstruction presets and investigated systematic bias, individual-patient disagreement, and equivalence between reconstruction settings. METHODS: Forty patients with mCRPC undergoing 68Ga-PSMA-11-PET/CT were retrospectively analyzed. PSMA-TV was quantified using three segmentation approaches: a fixed SUV threshold of 4.0 (T1), a liver-referenced adaptive threshold based on physiological liver uptake (T2), and a lesion-specific 41% SUVmax threshold (T3). Two reconstruction presets differing in image reconstruction parameters were compared. Systematic differences were assessed using signed differences, while individual disagreement was evaluated using absolute differences and median absolute percentage differences. Agreement was assessed using intraclass correlation coefficients (ICC) and logarithmic Bland-Altman analysis. Formal equivalence testing was performed using two one-sided tests (TOST) with exploratory margins of ± 10%, ± 20%, and ± 30% of mean PSMA-TV. RESULTS: PSMA-TV measurements demonstrated threshold-dependent reconstruction sensitivity. T3 showed the largest reconstruction-related variability, with a median signed relative difference of - 53.9% and markedly increased median absolute percentage difference (53.9%). In contrast, T1 and T2 showed substantially lower proportional disagreement (12.7% and 12.1%, respectively). T2 demonstrated the smallest systematic bias between reconstructions (median signed difference 0.4 mL; relative difference 1.1%) compared with T1 (16.9 mL; 9.0%). ICC values indicated high consistency for T1 (0.96; 95% CI, 0.93-0.98) and T2 (0.97; 95% CI, 0.94-0.98), whereas T3 showed lower precision (0.82; 95% CI, 0.29-0.93). Log-ratio Bland-Altman analysis demonstrated no evidence of proportional bias for any threshold. T2 was the only approach demonstrating equivalence within the strictest exploratory ± 10% margin. CONCLUSIONS: Reconstruction-dependent effects on PSMA-TV are strongly influenced by segmentation methodology. Liver-referenced adaptive thresholding minimized systematic reconstruction-related bias and demonstrated the highest robustness among evaluated approaches, although individual variability was not completely eliminated. Relative SUVmax-based segmentation showed substantially greater susceptibility to reconstruction changes. These findings support further evaluation of liver-referenced thresholding for standardized PSMA-TV assessment in longitudinal and multicenter settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Metabolic Tumor Volume Is More Accurate Than SUV Metrics in PSMA-PET/CT Analysis Across Different PET/CT Scanners.Clinical nuclear medicine · 2026
- Prognostic Value of Baseline High-Uptake PSMA Tumor Volume Fraction in Metastatic Castration-Resistant Prostate Cancer Patients Treated with [177Lu]Lu-PSMA Radioligand Therapy.Cancers · 2026
- Test-retest repeatability of deep learning-enabled quantitative PET parameters and PROMISE criteria-based lesion index in 18F-DCFPyL PSMA-PET/CT.European journal of nuclear medicine and molecular imaging · 2026
- Predictive Value of Pre-treatment Ga-68 PSMA-11 PET/CT Volumetric Parameters for Toxicity in Lu-177 PSMA-617 Therapy.Nuclear medicine and molecular imaging · 2026
- Single-time-point renal TIA estimation, sparse SPECT/CT data, and nonlinear mixed-effects modelling in [177Lu]Lu-PSMA-617 therapy.Zeitschrift fur medizinische Physik · 2026
- [18F]F-Prostate-specific Membrane Antigen-1007 and [68Ga] Ga-Prostate-specific Membrane Antigen-11 Positron Emission Tomography in Prostate Cancer: Do Standardized Uptake Value Correlations Dictate Choice?Journal of medical physics · 2026