Patient-specific three-dimensional titanium plate versus conventional two-miniplate fixation for mandibular angle fractures: a randomized clinical trial.
Asmaa M Abd Elfattah, Mostafa M Eldibany, Ragab S Hassan, Mona S Oraby
Oral and Maxillofacial Surgery, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. asmaa.abdelfattah.dent@alexu.edu.eg. · Oral and Maxillofacial Surgery, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
Key points
From the paper's conclusion- Conclusions Patient-specific three-dimensional titanium plate fixation was associated with shorter intraoperative time and lower early postoperative pain and edema.
Abstract
BACKGROUND: Mandibular angle fractures are clinically challenging because of their anatomical complexity and biomechanical loading. Conventional two-miniplate fixation requires intraoperative plate adaptation and transbuccal instrumentation. Patient-specific three-dimensional titanium plates are designed to conform to individual mandibular anatomy and may facilitate intraoperative fixation. This study aimed to clinically and radiographically evaluate patient-specific three-dimensional titanium plate versus conventional two mini-plate fixation in the management of mandibular angle fractures. METHODS: Sixteen patients with recent mandibular angle fractures were randomly allocated into two equal groups (n = 8). Group I underwent fixation using a patient-specific three-dimensional titanium plate positioned according to the preoperative virtual plan, whereas Group II received conventional two-miniplate fixation. The primary outcome was functional recovery assessed by maximal mouth opening (MMO). Secondary outcomes included intraoperative time, postoperative pain, facial edema, postoperative occlusion, wound healing, and CT bone density measurements in Hounsfield units (HU). Clinical outcomes were evaluated on postoperative days 1, 7, 14, and 30, whereas bone density was assessed immediately postoperatively and after 4 months. RESULTS: Intraoperative time was shorter in the patient-specific plate group than in the conventional two-miniplate group (40.00 ± 9.35 vs. 73.25 ± 11.22 min; P < 0.001). Postoperative pain was lower in the patient-specific plate group on postoperative day 1 (P = 0.015), while facial edema was lower on postoperative days 1 (P = 0.012) and 7 (P = 0.031). No statistically significant between-group differences were detected in maximal mouth opening, postoperative occlusion, Landry wound healing index scores, or CT bone density at the four-month follow-up. One patient in each group developed wound dehiscence, with complete healing after conservative management. CONCLUSIONS: Patient-specific three-dimensional titanium plate fixation was associated with shorter intraoperative time and lower early postoperative pain and edema. No statistically significant between-group differences were detected in the other assessed clinical and radiographic outcomes during the four-month follow-up. TRIAL REGISTRATION: The study was retrospectively registered at ClinicalTrials.gov (NCT07390734) on 29 January 2026.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Finite element analysis of patient specific three-dimensional titanium plate versus conventional two miniplate fixation for mandibular angle fractures.BMC oral health · 2026
- A novel plate design versus two conventional miniplates for treatment of mandibular angle fractures (a pilot randomized controlled clinical trial)BMC Oral Health · 2026
- Three-dimensional versus conventional miniplates in the management of mandibular angle fractures: A systematic review and meta-analysis.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026
- Evaluation of Locked Plates Versus 3-Dimensional Plates for Fixation of Mandibular Angle Fractures: A Clinical and Radiologic Study.The Journal of craniofacial surgery · 2026
- Comparative effectiveness of one versus two miniplates in the management of mandibular angle fractures: a systematic review and meta-analysis.The British journal of oral & maxillofacial surgery · 2026
- Assessment of accuracy and efficiency of guided fixation of customized 3D miniplates vs Champy's technique in stabilization of mandibular angle fractures: A randomized controlled trial.Clinical oral investigations · 2026