Does the biplane three-dimensional miniplate design provide stable fixation for mandibular angle fractures? A clinical study and proposal for novel radiographic criteria.
Kazem Khiabani, Mohammad Hosein Amirzade-Iranaq, Shahriyar Shabaninia
Department of Oral and Maxillofacial Surgery, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. · Postgraduate Student, Student Research Committee, Department of Oral Medicine, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.
Key points
From the paper's conclusion- Biplane 3D miniplate fixation shows promising results in the management of MAFs with minimal complications, suggesting that it is safe and effective. Concomitant management of displaced mandibular fractures does not seem to affect treatment outcomes.
Abstract
BACKGROUND: The posterior anatomical position and complex biomechanics of mandibular angle fractures (MAF) make their management more complicated than other mandibular fractures. The shortcomings of semi-rigid and rigid fixations have led to the development of a biplane three-dimensional (3D) miniplate design to fixate angle fractures in two perpendicular planes. The aim is to determine whether using a Biplane 3D miniplate could provide a feasible, effective, and reliable fixation for displaced MAFs. MATERIALS AND METHODS: This prospective, quasi-experimental, clinical study was conducted on adult patients with displaced MAFs. The primary outcome (occlusion) and secondary clinical outcomes (fracture stability and adequate mouth opening) were recorded in the first 2 weeks and the 2nd and 6th months postoperative. Appropriate reduction (secondary outcome) was assessed with novel radiographic criteria in the vertical and horizontal planes. Statistical analysis was performed using SPSS version 22 and included Fisher's exact and Chi-square tests. The level of significance was set at P < 0.05. RESULTS: Twenty-one patients with MAFs (nine isolated fractures) were operated on and followed for 3-6 months (mean: 4.95 months). Only two cases (9.52%) in the nonisolated fracture group showed mild occlusal derangement, which resolved with heavy elastic therapy. Adequate mouth opening was gradually resumed in both groups within the 1st month. No postfixation complications were observed. Radiographic criteria measurement revealed 14.29% and 28.6% mild vertical and horizontal radiographic malalignment without detectable clinical signs. CONCLUSION: Biplane 3D miniplate fixation shows promising results in the management of MAFs with minimal complications, suggesting that it is safe and effective. Concomitant management of displaced mandibular fractures does not seem to affect treatment outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Locked Plates Versus 3-Dimensional Plates for Fixation of Mandibular Angle Fractures: A Clinical and Radiologic Study.The Journal of craniofacial surgery · 2026
- A novel plate design versus two conventional miniplates for treatment of mandibular angle fractures (a pilot randomized controlled clinical trial)BMC Oral Health · 2026
- Finite element analysis of patient specific three-dimensional titanium plate versus conventional two miniplate fixation for mandibular angle fractures.BMC oral health · 2026
- Patient-specific three-dimensional titanium plate versus conventional two-miniplate fixation for mandibular angle fractures: a randomized clinical trial.BMC oral health · 2026
- Biomechanical Comparison of Monoplanar and Biplanar Miniplate Fixation for Unfavorable Mandibular Angle Fractures: A Finite Element Analysis.Cureus · 2026
- Three-dimensional versus conventional miniplates in the management of mandibular angle fractures: A systematic review and meta-analysis.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026