Biomechanical study of a novel external fixation frame controlling postoperative loss of reduction in thoracolumbar fractures: Finite element analysis
Hui Guo, Jiahao Feng, Yanyan Xue, Kun Wang, Ming Hao, Shaobo Nie
Key points
From the paper's conclusion- Conclusion Theoretically, these biomechanical features of MAEF may lower the risk of implant failure and post-traumatic kyphosis and facilitate fracture healing, supporting its potential for minimally invasive treatment of thoracolumbar burst fractures.
Abstract
Objective This study aims to investigate the biomechanical characteristics of percutaneous pedicle screw fixation combined with a novel external fixation device (Micro-Adjustable External Fixation - MAEF) for minimally invasive spinal fracture treatment using finite element analysis, providing theoretical support for clinical application. Methods We simulated an L1 vertebral fracture and constructed two finite element models: CASE 1: Micro-Adjustable External Fixation (MAEF), CASE 2: Percutaneous Short-Segment Intermediate Screw Fixation (PSISF). Under load control, we recorded the percentage change in ROM values before and after fixation for both models, along with maximum stress values at the fixation system, fractured vertebra (L1), T12 inferior endplate, and L2 superior endplate. Results Under all loading conditions, the ROM of the MAEF model was normalized to the ROM of the intact T11–L3 model, ranging from 8.4% to 15.5%. The ROM of the PSISF model was normalized to the intact T12–L2 model, ranging from 48.0% to 70.9%. Compared with the PSISF model, the MAEF model exhibited lower maximum stress values in the fixation system, fractured vertebra (L1), inferior endplate of T12, and superior endplate of L2. Furthermore, the maximum stress values for the fixation systems in both models occurred under lateral rotation conditions: the MAEF model’s fixation system peaked at 77.025 MPa during right rotation, while the PSISF model’s fixation system peaked at 170.97 MPa during left rotation. Significantly, contrary to the PSISF model results, the fractured vertebral body (L1) in the MAEF model exhibited markedly higher maximum stress values during flexion and extension compared to lateral bending, left rotation, and right rotation. These values were comparable to the maximum stresses observed in the PSISF model during flexion and extension, a phenomenon attributed to the MAEF model’s micro-adjustable system. Additionally, under all loading conditions, the maximum stress values at the adjacent vertebral endplates in the MAEF model were lower than those in the PSISF model. Conclusion Theoretically, these biomechanical features of MAEF may lower the risk of implant failure and post-traumatic kyphosis and facilitate fracture healing, supporting its potential for minimally invasive treatment of thoracolumbar burst fractures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026
- Cage-Orientation-Dependent Biomechanics of Endoscopic-Compatible Bidirectional Cortical Bone Trajectory-Modified Translaminar Facet Screw Fixation versus Bilateral Percutaneous Pedicle Screw Fixation in Osteoporotic TLIF: A Finite Element Study.Medical engineering & physics · 2026
- Biomechanical comparison of laminoplasty and in-site regrafting versus laminectomy with pedicle screw fixation for localized thoracic pathological ossification of the ligamentum flavum: a finite element analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Finite Element Comparison of Unilateral and Bilateral Polymethylmethacrylate Vertebral Fixation in the Canine Thoracolumbar Spine.Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2026
- Biomechanical effects of different bone conditions on oblique lumbar interbody fusion augmented with various fixation options: a finite element analysis.Frontiers in bioengineering and biotechnology · 2026
- Assessing the Clinical Utility of Finite Element Analysis Using Post-operative CT-Derived Models: A Material Comparison of Multi-level Spinal Fusion ConstructsbioRxiv · 2026