Finite Element Comparison of Unilateral and Bilateral Polymethylmethacrylate Vertebral Fixation in the Canine Thoracolumbar Spine.
Yuki Kikuchi, Fumitaka Takahashi, Shinya Yamaguchi, Yasushi Hara
School of Veterinary Medicine, Nippon Veterinary and Life Science University, Laboratory of the Veterinary Surgery, Tokyo, Japan, Musashino.
Key points
From the paper's conclusion- Bilateral vertebral fixation provided greater stabilization than uni-VF. Under the evaluated conditions, the associated increases in adjacent-segment range of motion and stress were minimal, indicating a limited biomechanical increase in adjacent-segment loading.
Abstract
OBJECTIVE: This study aimed to perform a theoretical finite element analysis comparing the biomechanical effects of unilateral (uni-VF) and bilateral vertebral fixation (bi-VF) using polymethylmethacrylate following individualized mini-hemilaminectomy-corpectomy (iMHC) of the canine thoracolumbar spine, focusing on range of motion and stress distribution. STUDY DESIGN: Using computed tomography data from a healthy Beagle dog, the following three-dimensional finite element models of the T12-L4 vertebrae were generated: (1) intact, (2) left-sided iMHC without fixation, (3) uni-VF (left side only) using 2.4-mm locking head screws embedded in polymethylmethacrylate after left-sided iMHC and (4) bi-VF using bilateral 2.4-mm locking head screws and polymethylmethacrylate after left-sided iMHC. Each model was subjected to a pure moment force equal to 2 N × m in six directions. Range of motion and equivalent stress were quantified and visualized at both treated and adjacent intervertebral levels. RESULTS: At the treated level, bi-VF resulted in markedly lower range of motion than uni-VF, accompanied by small increases in adjacent-segment range of motion. Equivalent stress in adjacent discs was slightly higher following bi-VF than following uni-VF but remained small relative to the reduction in range of motion at the treated level. CONCLUSION: Bilateral vertebral fixation provided greater stabilization than uni-VF. Under the evaluated conditions, the associated increases in adjacent-segment range of motion and stress were minimal, indicating a limited biomechanical increase in adjacent-segment loading.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026
- Biomechanical comparison of laminoplasty and in-site regrafting versus laminectomy with pedicle screw fixation for localized thoracic pathological ossification of the ligamentum flavum: a finite element analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Biomechanical study on the interaction between the extent of lumbar vertebral lamina and facet joint removal and segmental stability: a finite element analysis.BMC musculoskeletal disorders · 2026
- A three-dimensional finite element-based biomechanical properties analysis of the 10th thoracic vertebra invaded by bone metastases for clinical procedure optimization.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Biomechanical comparative analysis of minimally invasive decompression and minimally invasive fusion with internal fixation in the treatment of lumbar spinal stenosis with degenerative spondylolisthesis: a finite element study.BMC musculoskeletal disorders · 2026
- Biomechanical comparison of multirod constructs for severe thoracolumbar Pott's deformity following posterior vertebral column resection: a finite element study.Asian spine journal · 2026