Application of three-dimensional visualization reconstruction technology through CT to quantitatively measure diastasis recti abdominis
Qi Zhang, Xiaojian Fu, Qinghui Zhang, Yulan Zhu, Lingfeng Chen, Kai He
Key points
From the paper's conclusion- These findings suggest that 3DVR may offer additional three-dimensional anatomical characterization when CT images are available from appropriately justified examinations; however, the approximately 6-hour reconstruction time per case, lack of a reference standard, and absence of clinical-outcome validation currently limit routine implementation.
Abstract
Background Diastasis recti abdominis (DRA) is characterized by widening of the linea alba without a true fascial defect, but conventional ultrasound primarily provides linear measurements and two-dimensional CT approaches commonly rely on geometric assumptions for volumetric estimates. Whether CT-based three-dimensional visualization reconstruction (3DVR) provides additional quantitative characterization and systematically different measurements remains uncertain. We therefore compared quantitative measurements of DRA obtained using CT-based 3DVR, two-dimensional CT ellipsoid approximation (2D-EA), and ultrasound (US) in an exploratory methodological study. Methods Twenty patients with DRA were included in this exploratory observational methodological comparison. CT-based 3DVR was used to quantify inter-rectus distance (IRD), defect surface area (DSA), non-hernial abdominal wall bulging-space volume (HSV; abbreviation retained from the original dataset), abdominal cavity volume (ACV), and loss of domain (LOD). A two-dimensional CT ellipsoid approximation (2D-EA) was used for comparison, and all participants also underwent ultrasound measurement of IRD. LOD was calculated as HSV/(HSV + ACV) × 100%. Normality of paired differences was evaluated using the Shapiro-Wilk test. Paired t-tests were used when normality was supported, with Wilcoxon signed-rank tests as sensitivity analyses. Exact P values, 95% confidence intervals, Cohen’s dz effect sizes, Pearson correlations, and a Bonferroni-adjusted significance threshold of P < 0.0071 were reported. Results 3DVR yielded higher ACV than 2D-EA (5340.51 ± 818.53 vs. 4497.82 ± 932.28 cm³; mean paired difference, 842.69 cm³; 95% CI, 577.01-1108.36; P < 0.001; Cohen’s dz = 1.484), higher HSV (248.71 ± 128.95 vs. 190.28 ± 107.05 cm³; difference, 58.43 cm³; 95% CI, 27.53–89.33; P = 0.0008; dz = 0.885), and higher IRD (7.88 ± 1.50 vs. 7.59 ± 1.40 cm; difference, 0.29 cm; 95% CI, 0.11–0.47; P = 0.0035; dz = 0.745). LOD did not differ significantly (4.37 ± 2.05% vs. 3.90 ± 1.69%; P = 0.0886). Mean DSA measured by 3DVR was 115.15 ± 27.79 cm². IRD was also higher with 3DVR than with ultrasound (7.88 ± 1.50 vs. 6.82 ± 1.16 cm; difference, 1.06 cm; 95% CI, 0.40–1.72; P = 0.0034; dz = 0.747), whereas the 2D-EA-versus-ultrasound difference did not meet the Bonferroni-adjusted threshold ( P = 0.0314). The paired differences were compatible with normality, and the principal findings were unchanged using the Bonferroni-adjusted threshold of P < 0.0071. Conclusion CT-based 3DVR demonstrated systematic differences in volumetric and linear measurements compared with 2D-EA and ultrasound and provided DSA, which was not obtainable using the ellipsoid approximation. These findings suggest that 3DVR may offer additional three-dimensional anatomical characterization when CT images are available from appropriately justified examinations; however, the approximately 6-hour reconstruction time per case, lack of a reference standard, and absence of clinical-outcome validation currently limit routine implementation. Future studies should prioritize workflow automation, standardized multimodal acquisition, reproducibility testing, and prospective evaluation of whether 3D-derived measurements influence treatment planning or outcomes. Clinical trial number Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-planar reconstruction and 3D volume rendering as tools of anatomical dissection and morphometry on the example of cadaveric study of inferior medial genicular artery : Comparison of visualisation of branches of the inferior medial genicular artery using 3D volume reconstruction, MPR, and a fresh-frozen cadaver.Surgical and radiologic anatomy : SRA · 2026
- Intra- and Inter-Rater Reliability of Inter-Recti Distance Measurement Using B-Mode and Panoramic Ultrasound ImagingJournal of Clinical Medicine · 2026
- Prevalence and risk factors of diastasis recti abdominis and a proposed hierarchical framework for clinical decision makingDiscover Medicine · 2026
- Inter-Device Agreement Between Vectra H2 and LifeViz Mini for Nasolabial Volumetric Assessment After Thread Lifting: A Post Hoc Method-Comparison Study.Aesthetic surgery journal. Open forum · 2026
- Population-based ultrasound reference values for inter-rectus distance: threshold prevalence, percentiles, and the limitations of fixed cutoffs.Hernia : the journal of hernias and abdominal wall surgery · 2026
- Reliability of shear wave elastography measurements of the linea alba: an intraclass correlation and Bland-Altman analysis.BMC women's health · 2026