Inter-Device Agreement Between Vectra H2 and LifeViz Mini for Nasolabial Volumetric Assessment After Thread Lifting: A Post Hoc Method-Comparison Study.
Pornsuk Yamlexnoi, Woramate Bhorntarakcharoen, Wilailuck Phokai, Thanakorn Woramongkol, Onjira Meethong, Thitiwat Junpunyawong, Apichaya Jutaphonrakul, Natsuda Sanrit,
Key points
From the paper's conclusion- Objectives To evaluate agreement between Vectra H2 and LifeViz Mini for nasolabial volumetric assessment after thread lifting.
Abstract
Objective quantification of subtle facial volume change requires reliable 3-dimensional imaging, but measurements from different systems may not be equivalent. The aim of this study was to evaluate agreement between Vectra H2 and LifeViz Mini for nasolabial volumetric assessment after thread lifting. This post hoc secondary retrospective method-comparison study analyzed paired images prospectively acquired in a parent study. Fifteen women treated with absorbable polydioxanone mesh threads contributed 74 paired side-specific measurements across 43 participant visits. A standardized 1 cm2 nasolabial region of interest was analyzed with Vectra H2 (Canfield Scientific, Inc., Parsippany, NJ) and LifeViz Mini (QuantifiCare S.A., Valbonne, France). Agreement was assessed using an absolute-agreement intraclass correlation coefficient (ICC), Bland-Altman analysis, and paired testing. A participant-level sensitivity analysis averaged bilateral measurements within visits and then averaged visits within each participant. The mean age was 41.87 ± 7.85 years (range, 34-56 years). The paired measurements did not differ significantly (exact 2-sided Wilcoxon P = .356); the median LifeViz Mini-minus-Vectra H2 difference was 0.00108 cm3. The ICC was 0.977 (95% CI, 0.963-0.985). Mean bias was 0.00045 cm3, with limits of agreement from -0.00924 to 0.01013 cm3. Participant-level findings were consistent (P = .804; ICC = 0.953; mean bias, 0.00019 cm3). Vectra H2 and LifeViz Mini produced highly concordant nasolabial volume-change measurements under standardized conditions. The participant-level sensitivity analysis supported the robustness of the findings, although larger prospective studies are required. Level of Evidence: 3 (Diagnostic).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-planar reconstruction and 3D volume rendering as tools of anatomical dissection and morphometry on the example of cadaveric study of inferior medial genicular artery : Comparison of visualisation of branches of the inferior medial genicular artery using 3D volume reconstruction, MPR, and a fresh-frozen cadaver.Surgical and radiologic anatomy : SRA · 2026
- Evaluation of Four 3D Facial Scanning Technologies: From Photogrammetry to Structured-Light Systems in Clinical DentistryDentistry Journal · 2026
- Application of three-dimensional visualization reconstruction technology through CT to quantitatively measure diastasis recti abdominisBMC Medical Imaging · 2026
- Trueness and precision of smartphone-based 3D scan in the assessment of facial edema in orthognathic surgeryJournal of Oral Biology and Craniofacial Research · 2026
- Comparative evaluation of mixed reality, CTA-based digital guide, and hand-held Doppler for anterolateral thigh perforator localization in head and neck reconstruction.International journal of oral and maxillofacial surgery · 2026
- Efficacy and Safety of Poly-L-Lactic Acid Microspheres for Temporal Hollowing Correction: A Multicenter, Randomized, No-Treatment-Controlled, Evaluator-Blinded Trial.Aesthetic plastic surgery · 2026