Multi-planar reconstruction and 3D volume rendering as tools of anatomical dissection and morphometry on the example of cadaveric study of inferior medial genicular artery : Comparison of visualisation of branches of the inferior medial genicular artery using 3D volume reconstruction, MPR, and a fresh-frozen cadaver.
Julia Szopa, Laura Fortuna, Paweł Gębski, Filip Lipiński, Bogdan Ciszek, Beata Ciszkowska-Łysoń, Robert Śmigielski
Student Research Society, Department of Descriptive and Clinical Anatomy, Center for Biostructure Research, Medical University of Warsaw, Warsaw, Poland. · Department of Descriptive and Clinical Anatomy, Center for Biostructure Research, Medical University of Warsaw, Warsaw, Poland.
Key points
From the paper's conclusion- Four independent observers performed "digital dissections" of the inferior medial genicular artery across two DICOM viewing platforms: RadiANT DICOM Viewer 2025.2 (64-bit) and Horos v4.0.0 RC5.
Abstract
Cadaveric dissection is a traditional method used to reveal deep-seated anatomical structures; however, it is inherently time-consuming and irreversible, preventing the correction of procedural errors. To address these limitations, this feasibility study proposes a novel computer-assisted, "digital dissection" framework designed to accelerate workflow, allow error mitigation, and enable repeatable analysis of a single specimen. Four independent observers performed "digital dissections" of the inferior medial genicular artery across two DICOM viewing platforms: RadiANT DICOM Viewer 2025.2 (64-bit) and Horos v4.0.0 RC5. Morphometric measurements were recorded at predefined reference points corresponding to arterial branching sites. Inter-observer variability was evaluated, and the resulting dataset was validated against multiplanar reconstruction (MPR) metrics-the standard radiological benchmark for vascular assessment. Statistical analysis revealed no significant difference between three-dimensional volume rendering (3D VR) and MPR in assessing vessel dimensions for structures with a diameter exceeding (dMPR=0.950 mm). For vessels > 0.95 mm, 3D-VR and MPR yielded no statistically significant difference (p = 0.086), a strong Pearson correlation (r = 0.971), and a Bland‑Altman mean bias of -0.03 mm (95% LoA: - 0.14 to +0.07 mm). Furthermore, morphological consistency was maintained regardless of vessel caliber. The integration of 3D VR and MPR modalities would offer a cost-effective, highly reproducible, non-invasive tool for both educational and research applications in vascular analysis. Moreover, these measurements exhibit strong stability across different software platforms and operators, showing an absence of systematic bias with only minor variations attributable to human error or minor misalignment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of three-dimensional visualization reconstruction technology through CT to quantitatively measure diastasis recti abdominisBMC Medical Imaging · 2026
- Inter-Device Agreement Between Vectra H2 and LifeViz Mini for Nasolabial Volumetric Assessment After Thread Lifting: A Post Hoc Method-Comparison Study.Aesthetic surgery journal. Open forum · 2026
- Comparative evaluation of mixed reality, CTA-based digital guide, and hand-held Doppler for anterolateral thigh perforator localization in head and neck reconstruction.International journal of oral and maxillofacial surgery · 2026
- Diameter measurement of tubular structures on CT angiography, 3D rotational angiography, and 2D digital subtraction angiography against caliper ground truth: A phantom study of surrogates for intracranial vessels.medRxiv · 2026
- Feasibility study for 3D quantitative angiography in internal carotid aneurysms using in silico biplane imaging and 3D vascular geometry constraints.Medical image analysis · 2026
- Optimising digital volume correlation across materials: a practical framework for accuracy and spatial resolutionbioRxiv · 2026