Biomechanical comparison of parallel versus convergent screw fixation in Zadek osteotomy.
Cesar Ramirez, Seif El Masry, Taylor Rakauskas, Gabrielle Meli, Jim Fitzsimmons, Alexander Hooke, Nathan Flath, Joshua Bland,
Department of Orthopedic Surgery, Mayo Clinic, Jacksonville, USA. · Department of Orthopedic Surgery, Mayo Clinic, Jacksonville, USA. rakauskas.taylor@mayo.edu.
Key points
From the paper's conclusion- Parallel and convergent screw constructs demonstrated comparable initial fixation strengths following Zadek osteotomy, suggesting screw trajectory may have limited impact on construct stability. Further studies are needed to validate these findings clinically.
Abstract
PURPOSE: Zadek osteotomy is an increasingly utilized treatment for insertional Achilles tendinopathy (IAT), although an optimal fixation strategy remains unclear. This cadaveric study compared biomechanical outcomes of parallel and convergent screw fixation constructs following Zadek osteotomy. We hypothesized that convergent screw fixation would demonstrate greater stability. METHODS: Five paired fresh-frozen human calcanei (10 specimens) underwent simulated Zadek osteotomy, receiving paired parallel and convergent screw fixations on contralateral limbs. Specimens were tested using a servohydraulic system and motion tracking. Axial loading was applied until construct failure. Primary biomechanical outcomes included construct stiffness, load at 2 mm displacement, ultimate load to failure, and displacement at failure. Comparisons were performed using paired t-tests. One specimen was excluded from final analysis due to premature failure. RESULTS: No significant differences were observed between parallel and convergent constructs for any biomechanical outcome. Mean stiffness was 1415 ± 1337 N/mm for parallel constructs and 1360 ± 952 N/mm for convergent constructs (p = 0.96). Load at 2 mm displacement measured 707 ± 289 N and 892 ± 401 N, respectively (p = 0.54). Ultimate load to failure was 915 ± 266 N and 1065 ± 401 N, respectively (p = 0.55). Displacement at failure was similar between groups (p = 0.45). The combination shear-compression sliding at the osteotomy interface was the predominant mechanism of failure in both groups. CONCLUSION: Parallel and convergent screw constructs demonstrated comparable initial fixation strengths following Zadek osteotomy, suggesting screw trajectory may have limited impact on construct stability. Further studies are needed to validate these findings clinically.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Impact of Hinge Position and Wedge Orientation in Zadek Osteotomy across Different Foot Morphologies: A Virtual Surgical Simulation Study.Foot & ankle orthopaedics · 2026
- Intraarticular calcaneal fractures: biomechanical analysis of two fixation constructs.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
- Greater deformation and lower stiffness, but similar ultimate failure strength with fixed-loop cortical suspensory device compared to metal interference screw for femoral fixation of bone-patellar tendon-bone grafts in anterior cruciate ligament reconstruction.Journal of experimental orthopaedics · 2026
- Biomechanical Evaluation of Crossed Screw Fixations With Different Head Designs for First Tarsometatarsal Joint Arthrodesis.Foot & ankle specialist · 2026
- Bioplating demonstrates increasing micromovement during cyclic loading after anterior closed wedge high tibial osteotomy despite no significant difference in failure load compared to angle-stable plate fixation.Journal of experimental orthopaedics · 2026
- Computational biomechanical analysis of medial displacement calcaneal osteotomy placement and orientation.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026