Comparison of 3 Headless Compression Screw Types for Proximal, Waist, and Distal Scaphoid Fractures.
Joanne Y Zhou, Spencer B Chambers, J Daniel Thompson, Michael B Gottschalk, Eric R Wagner, Nina Suh
Emory University, Atlanta, GA, USA. · St. Joseph's Hospital, London, ON, Canada.
Key points
From the paper's conclusion- As measured at the flush insertion point, the Acutrak 3 screw demonstrated the highest compressive force for models of proximal and waist fractures. Fully threaded variable pitch screw design resulted in greater simulated fracture compression than Herbert-style screws, which do not have central threads. Understanding the interplay of screw characteristics with various fracture patterns is important when selecting an operative construct that optimizes fracture stability.
Abstract
INTRODUCTION: Headless compression screws are a popular fixation construct for scaphoid fractures as they can maintain reduction and provide fracture compression without implant prominence. The purpose of this study is to characterize fracture compression in models of proximal, waist, and distal scaphoid fractures for 3 types of headless compression screws. METHODS: Three Sawbones models representing proximal, waist, and distal fractures were used to test the biomechanical properties of three 20-mm screws (Acumed Acutrak 3 Mini, Arthrex Compression FT Mini, Medartis Cannulated HD10). Screws were inserted in an antegrade fashion at a rate of 30 rpm using a DC motor mounted to the actuator of an Instron load frame. Compressive force was recorded at the point of flush insertion and compared using analysis of variance and Student t test. RESULTS: Acutrak 3 achieved the highest compression in models of proximal and waist fractures, and the Acutrak 3 and Arthrex FT screws demonstrated similar compression in models of distal fractures with antegrade insertion. Both the Acutrak 3 and Arthrex FT screws demonstrated significantly less compression in distal fractures when compared with proximal and waist fractures. CONCLUSIONS: As measured at the flush insertion point, the Acutrak 3 screw demonstrated the highest compressive force for models of proximal and waist fractures. Fully threaded variable pitch screw design resulted in greater simulated fracture compression than Herbert-style screws, which do not have central threads. Understanding the interplay of screw characteristics with various fracture patterns is important when selecting an operative construct that optimizes fracture stability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical comparison between two headless screw configurations for fixation of coronal shear capitellum humeri fractures.Clinical biomechanics (Bristol, Avon) · 2026
- Biomechanical Evaluation of Crossed Screw Fixations With Different Head Designs for First Tarsometatarsal Joint Arthrodesis.Foot & ankle specialist · 2026
- Headless Compression Screws May Reduce Symptomatic Hardware After Medial Malleolus Fixation: A Comparative Cohort Study.Journal of orthopaedic trauma · 2026
- Two headless cannulated screws have a higher maximum failure load than screw-and-pin fixation at a 70° fracture angle in 3-dimensionally printed canine femoral neck models.American journal of veterinary research · 2026
- Internal Fixation Bone Mass Index (IFBM) and Biomechanical Performance of Different Fixation Methods for Herscovici Type B and Type C Medial Malleolar Fractures.The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons · 2026
- Loose Screw or No Screw? A Biomechanical Study to Answer a Common Intraoperative Dilemma.Hand (New York, N.Y.) · 2026