Tangential volumetric modulated arc therapy reduces cardiac and contralateral low-dose exposure compared with continuous volumetric modulated arc therapy in postoperative breast radiotherapy.
Anne Caroline Knöchelmann, Mirko Fischer, Kathrin Burchardt, Daniela Meinecke, Jan-Niklas Becker
Department of Radiotherapy, Hannover Medical School, Carl-Neuberg-Strasse 1, Hannover, 30625, Germany.
Key points
From the paper's conclusion- In a clinically heterogeneous paired cohort that included boost irradiation, regional nodal irradiation, and deep-inspiration breath hold, tangential volumetric modulated arc therapy reduced cardiac and contralateral low-dose exposure while preserving target coverage.
Abstract
BACKGROUND AND PURPOSE: Tangential volumetric modulated arc therapy may combine rotational conformality with tangential beam geometry. We compared tangential with continuous-arc volumetric modulated arc therapy for postoperative breast radiotherapy with deliberately matched target coverage, focusing on cardiac and contralateral low-dose exposure. MATERIAL AND METHODS: Fifty-four patients were included in this paired planning study. For each patient, the clinically delivered tangential plan and a matched continuous-arc plan were evaluated. Target coverage was matched by clinical-target-volume D95% and planning-target-volume D2%. Dose-volume endpoints, low-dose area-under-the-curve metrics, delta dose-volume histograms, subgroup interactions, and mechanistic organ-equivalent-dose surrogates were evaluated. RESULTS: Target coverage and homogeneity were comparable, while conformity was higher with tangential planning (p = 0.006). Tangential planning reduced mean heart dose from 1.34 to 1.17 Gy (p < 0.001), contralateral lung mean dose from 0.94 to 0.57 Gy, and contralateral breast mean dose from 1.16 to 0.76 Gy (both p < 0.001). Mechanistic organ-equivalent-dose surrogates were reduced by 37.0% for the contralateral lung and 32.7% for the contralateral breast. Exploratory interaction analyses did not identify statistically significant interactions by laterality, deep-inspiration breath hold, simultaneous integrated boost, or regional nodal irradiation. CONCLUSIONS: In a clinically heterogeneous paired cohort that included boost irradiation, regional nodal irradiation, and deep-inspiration breath hold, tangential volumetric modulated arc therapy reduced cardiac and contralateral low-dose exposure while preserving target coverage.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of heart-sparing radiation techniques for left-sided breast cancer: DIBH combined with tangential 3D radiation vs. conventional and tangential VMAT techniquesRadiation Oncology · 2026
- Feasibility and trade-offs of incorporating cardiac substructure dose constraints in left-sided breast volumetric modulated arc therapy planning.Radiation oncology journal · 2026
- Comparative Analysis of Arc Geometrical Configurations and Jaw Tracking for Peripheral Low-Dose Bath in Whole Breast VMAT.Technology in cancer research & treatment · 2026
- Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boostActa Oncologica · 2026
- Dosimetric comparison of organs at risk exposure in multicatheter high-dose-rate interstitial brachytherapy vs. VMAT-based APBI for real patient treatment plans.Journal of contemporary brachytherapy · 2026
- Radiobiological evaluation of hypofractionated vs. conventional VMAT for synchronous bilateral breast cancer: a focus on regional nodal irradiation.Frontiers in medicine · 2026