Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

Biomechanical effects of far-cortex over-penetration in locking plate fixation: A finite element study.

Natig Valiyev, Cihan Zaman

Department of Orthopaedics and Traumatology, Ümraniye Training and Research Hospital, Istanbul, Turkey. · Department of Orthopaedics and Traumatology, Sarıkamış State Hospital, Kars, Turkey.

Key points

From the paper's conclusion
  • This study quantified the biomechanical consequences of incremental far-cortex over-penetration at terminal locking screw positions in a locking compression plate construct using a validated three-dimensional finite element model of a femoral diaphyseal fracture (AO/OTA 32-A3).

Abstract

This study quantified the biomechanical consequences of incremental far-cortex over-penetration at terminal locking screw positions in a locking compression plate construct using a validated three-dimensional finite element model of a femoral diaphyseal fracture (AO/OTA 32-A3). Four terminal screw engagement configurations were evaluated: unicortical fixation, fully contained bicortical fixation, 1-thread over-penetration (0.6 mm), and 3-thread over-penetration (1.8 mm). Axial compression (1000 N), torsional loading (±10 Nm), and cyclic dynamic loading (100-1000 N, 1 × 106 cycles) simulating the 8-week early postoperative period were applied. Model validation against published experimental data demonstrated agreement within 4% for all key biomechanical parameters. Fully contained bicortical fixation was the only configuration to remain below the predicted fatigue threshold, demonstrating the lowest peak von Mises stress (74.8 MPa) and a Miner's cumulative damage index of D = 0.291. Unicortical fixation (D = 1.103), 1-thread over-penetration (D = 1.362), and 3-thread over-penetration (D = 2.968) all exceeded the failure threshold (D ≥ 1.0). Under the loading conditions and material assumptions of the present finite element model, unicortical terminal fixation alone did not sustain simulated cyclic physiological loading during the pre-callus phase without exceeding the predicted fatigue damage threshold. These findings provide preliminary, model-dependent computational evidence suggesting that fully contained bicortical fixation may offer greater fatigue resistance, and that the biomechanical basis of current terminal screw placement guidelines warrants further experimental investigation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Biomechanical effects of far-cortex over-penetration in locking plate fixation: A finite element study — Science Skim