Optimizing Volar Lunate Facet Fracture Fixation: Finite Element Analysis and Cadaveric Testing.
Alireza Gholipour, Jonathan Lans, Alyssa Lee, Marco T Di Stefano, Augustus D Mazzocca, Abhiram R Bhashyam
Department of Orthopaedic Surgery, Enable Education and Research Facility, Massachusetts General Brigham Hospital, Harvard Medical School, Boston, Massachusetts, USA. · Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia.
Key points
From the paper's conclusion- We used finite element analysis (FEA) and cadaveric testing to identify failure mechanisms and determine how screw configuration alters load transfer.
Abstract
Volar lunate facet (VLF) fractures are prone to loss of reduction after volar plating. We used finite element analysis (FEA) and cadaveric testing to identify failure mechanisms and determine how screw configuration alters load transfer. A CT-derived radius model with a 10 × 15 × 5-mm VLF fragment was fixed with a 4-hole hook plate using locking and nonlocking (NL) screws. A 500-N radiolunate compressive load was applied, and von Mises stresses were quantified. Sensitivity analyses varied loading, bone density, fracture characteristics, and implant material. Ten distal radii underwent cyclic loading followed by load-to-failure testing; failure modes and locations were compared with FEA hotspots. FEA identified two stress concentrations: the distal plate contour/screw-hole region and the ulnar hook insertion into the VLF fragment. In the baseline 1[NL]&3[NL] construct, peak construct and radius stresses were 697.2 and 154.6 MPa. The 1[NL]&2[NL] configuration produced the lowest stresses (54.5 and 27.3 MPa), whereas locking hole 3 reduced construct stress to 587.2 MPa. Cadaver failure load was 1239.2 ± 438.5 N (range: 630.0-1990.1 N); failures were loss of reduction/fracture dislocation (4/10) or plate failure (6/10), with failure locations corresponding to FEA hotspots. Off-axis loading, reduced bone density, and fracture-line translation increased construct stress and altered hotspot location. FEA-predicted hook-fragment stress corresponded to loss of reduction, whereas distal plate stress corresponded to plate failure. Among modeled configurations, 1[NL]&2[NL] minimized construct and radius stress, although unbalanced cadaveric groups preclude claims of clinical superiority. These findings support fragment capture while minimizing distal plate stress.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical effects of far-cortex over-penetration in locking plate fixation: A finite element study.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus : a finite element and cadaveric study.Bone & joint research · 2026
- Dorsal subchondral arc line: A novel radiographic marker to avoid dorsal screw prominence during distal radius fixation with volar locking plates.Injury · 2026
- Finite Element Analysis of the Foot and Ankle: A Critical Review of Metatarsal Biomechanics, Hallux Valgus, Fixation, and Plantar LoadingBiomechanics · 2026
- Biomechanical comparison of palmar plate plus headless compression screw versus radiopalmar double plating in AO/OTA 23-C2.1 distal radius fracturesArchives of Orthopaedic and Trauma Surgery · 2026
- Development and Biomechanical Study of Micro Anatomic Universal Locking Plate for Talus Fractures.Orthopaedic surgery · 2026