Quantitative comparison of virtual non-contrast and true non-contrast computed tomography pulmonary angiography images across eight thoracic tissue types: A retrospective cross-sectional study.
Jiulong Yan, Ziyu Zhao, Xin Zhou, Yuxuan Chen, Ying Shen, Jin Gao, Xinxing Ma, Yue Teng
Department of Radiology, The First Affiliated Hospital of Soochow University, China. · Department of Medical Imaging Science, Suzhou Medical College of Soochow University, China.
Key points
From the paper's conclusion- ObjectiveTo evaluate the quantitative reliability of virtual non-contrast images derived from spectral computed tomography pulmonary angiography across eight thoracic tissues, assessing their feasibility as a true non-contrast substitute.MethodsIn this retrospective cross-sectional study, we analyzed 169 patients undergoing spectral computed tomography pulmonary angiography.
Abstract
ObjectiveTo evaluate the quantitative reliability of virtual non-contrast images derived from spectral computed tomography pulmonary angiography across eight thoracic tissues, assessing their feasibility as a true non-contrast substitute.MethodsIn this retrospective cross-sectional study, we analyzed 169 patients undergoing spectral computed tomography pulmonary angiography. Attenuation differences between true non-contrast and virtual non-contrast images were evaluated across eight anatomical regions. Statistical assessments included Bonferroni-corrected Wilcoxon signed-rank tests, Pearson correlation (r), Lin's concordance correlation coefficient, and Bland-Altman analysis.ResultsVirtual non-contrast performance showed four distinct patterns. (1) Excellent agreement. Lung parenchyma and erector spinae muscle demonstrated high absolute concordance (concordance correlation coefficient = 0.981 and 0.876, respectively) with clinically negligible biases (3.8 Hounsfield units and -1.0 Hounsfield units). (2) Moderate agreement. The aorta and pulmonary artery shared identical concordance correlation coefficient values (0.430) but exhibited divergent clinical threshold exceedances, primarily driven by a larger mean bias in the pulmonary artery (8.8 Hounsfield units). (3) Stable systematic offsets. The T6 vertebral body and mediastinal fat exhibited massive systematic biases (66.2 Hounsfield units and -11.1 Hounsfield units, respectively), leading to poor absolute agreement (concordance correlation coefficient = 0.390 and 0.531). However, both maintained strong linear correlations (r = 0.902 and 0.816) and extremely low outlier rates beyond the 95% limits of agreement. (4) Unacceptable agreement. The thyroid gland and superior vena cava yielded clinically unacceptable reliability due to proportional bias and beam-hardening artifacts. The physical true non-contrast acquisition accounted for 53.0% of the total effective radiation dose.ConclusionsSpectral virtual non-contrast imaging accurately substitutes true non-contrast imaging in the lung parenchyma and erector spinae muscle. Although major vessels show moderate reliability, the massive systematic underestimation in vertebral bone precludes its direct clinical use for quantitative assessment without validated mathematical correction factors. Intrinsically iodine-rich organs and structures prone to streak artifacts remain unsuitable for virtual non-contrast substitution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative Comparison of Virtual and True Noncontrast Lung Images in Photon-counting CT: Global and Regional Attenuation Assessment.Radiology · 2026
- Improvement of Lung Nodule Volumetric Accuracy with Photon-counting Computed Tomography Over Energy-integrating Computed Tomography in Low-dose ScreeningInvestigative Radiology · 2026
- Pulmonary nodule image quality and morphologic visualization with photon-counting detector CT: a scoping reviewEuropean Radiology Cardiovascular and Thoracic · 2026
- Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging.Diagnostics (Basel, Switzerland) · 2026
- PET Attenuation Map Generation for Brain Imaging from Virtual Non-Contrast and Virtual Non-Iodine Images Obtained with Photon Counting CT ScannersarXiv · 2026
- Diagnostic performance of liver virtual non-contrast and virtual unenhanced reconstructions derived from photon-counting detector CT of the upper abdomen.Abdominal radiology (New York) · 2026