Pulmonary nodule image quality and morphologic visualization with photon-counting detector CT: a scoping review
Felix Barajas Ordonez, Isaac Eli Martínez Safar, Ana M. Rendón-Garavito, Can Yüksel, Christiane Kuhl, Omar Andrés Pantoja-Burbano, Felipe Aluja-Jaramillo
Key points
From the paper's conclusion- Findings Photon-counting detector CT showed superior subjective image quality, additional morphologic features in 34%–73% of subsolid nodules, and 12%–18% lower doses versus energy-integrating detector CT.
Abstract
Objective To systematically map the available evidence on pulmonary nodule visualization quality using photon-counting CT (PCD-CT). Materials and methods This scoping review followed JBI methodology and PRISMA-ScR reporting standards. MEDLINE/PubMed, Embase, and Scopus were searched from January 2021 to January 2026. Studies evaluating pulmonary nodule visualization in adults or ex vivo human specimens using PCD-CT were included. Two reviewers independently screened records and extracted data; consistent with scoping review methodology, no formal risk-of-bias assessment was performed. Results Five studies (six records; 318 patients, mean age range 56–69 years) and 20 cadaveric lungs met the inclusion criteria. All studies used the same PCD-CT platform. Image quality: same-day comparisons showed superior subjective image quality with PCD-CT at 12%–18% lower radiation doses ( p < 0.001). Morphologic feature visualization: PCD-CT detected additional features in 34%–73% of subsolid nodules; ex vivo histological correlation demonstrated higher morphological concordance at 1024-matrix resolution. Nodule detection: ultra-low-dose PCD-CT maintained detection sensitivity of 0.94. Conclusion PCD-CT shows promise for improving pulmonary nodule visualization at reduced radiation doses. Evidence remains limited to single-center studies without clinical outcome validation, precluding implementation recommendations. Key Points Question Whether photon-counting detector CT improves image quality and morphologic characterization of pulmonary nodules compared with energy-integrating detector CT remains insufficiently mapped. Findings Photon-counting detector CT showed superior subjective image quality, additional morphologic features in 34%–73% of subsolid nodules, and 12%–18% lower doses versus energy-integrating detector CT. Relevance statement In single-center studies, photon-counting detector CT improved morphologic characterization of pulmonary nodules and reduced radiation exposure; clinical outcome validation is required before broad implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improvement of Lung Nodule Volumetric Accuracy with Photon-counting Computed Tomography Over Energy-integrating Computed Tomography in Low-dose ScreeningInvestigative Radiology · 2026
- Comparing Deep Learning Models for Lung Nodule Detection on Photon-Counting CT Images in a Non-Screening SettingmedRxiv · 2026
- Photon-counting detector CT for CT pulmonary angiography: a systematic review and meta-analysis.European radiology · 2026
- Photon-Counting Computed Tomography in the Era of Precision Medicine: Technological Advances, Artificial Intelligence Integration, and Multidisciplinary Clinical ApplicationsInternational Science Journal · 2026
- Ultra-Low-Dose Photon-counting Detector CT for Emphysema Assessment: A Head-to-Head Comparative Study with Low-Dose CTRadiology · 2026
- Quantitative Comparison of Virtual and True Noncontrast Lung Images in Photon-counting CT: Global and Regional Attenuation Assessment.Radiology · 2026