Multicenter Comparison of Cell Block Preparation Methods Using Matched Specimen Aliquots with Low and High Cellularity.
Vanessa Sofia Tavares, Rúben Rodrigues Roque, Margareta Strojan Flezar, Damjana Cimerman, Tinka Mohar Hajnšek, Marjeta Umek, Simona Gabric, Nina Hajdinjak,
Key points
From the paper's conclusion- This multicenter evaluation model enabled an objective comparison of CB preparation methods using matched specimen aliquots with predefined cellularity. The study validates the framework's capacity to detect protocol performance differences, providing a standardized tool for future quality assurance and the technological development in CB processing.
Abstract
INTRODUCTION: Inadequate cellularity remains a major limitation of cell block (CB) preparation. We aimed to develop a standardized framework for the objective assessment of CB preparation protocols to optimize existing techniques and evaluate emerging technologies. METHODS: Five laboratories processed matched low- and high-cellularity effusion aliquots into CBs using two HistoGel techniques (concave, butterfly) and the CytoPath Disc. Predefined serial hematoxylin and eosin (H&E) sections were evaluated for cellularity, cell distribution, morphological preservation, staining quality, and background using a 0-3 scale. An overall CB quality score (0-100) was calculated to benchmark performance. Methods were compared using one-way ANOVA with post-hoc testing to validate the model's discriminatory capacity. RESULTS: A total of 731 H&E sections from 147 CBs were evaluated. Overall CB quality scores were comparable between the HistoGel concave (74.87 ± 10.94) and butterfly methods (75.57 ± 12.09; P = .62), whereas the CytoPath Disc yielded significantly lower scores (53.45 ± 11.56; P < .001) across both low- and high-cellularity groups. H&E section cellularity demonstrated the greatest differences between methods, particularly in CBs prepared from low-cellularity aliquots (P < .001), and was the only parameter exhibiting variability across serial sections, occurring exclusively with the CytoPath Disc method. CONCLUSIONS: This multicenter evaluation model enabled an objective comparison of CB preparation methods using matched specimen aliquots with predefined cellularity. The study validates the framework's capacity to detect protocol performance differences, providing a standardized tool for future quality assurance and the technological development in CB processing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance Evaluation of an Artificial Intelligence-Assisted Digital Morphology System for Bone Marrow Aspirate Examination.International journal of laboratory hematology · 2026
- Bile Cell Block-Derived DNA for Next-Generation Sequencing in Cholangiocarcinoma: A Comparison With Surgical Specimens.Journal of hepato-biliary-pancreatic sciences · 2026
- B-179 Quantifying the Quality of HEp-2 Cell Slides to Ensure the Accuracy of Indirect Immunofluorescence Antinuclear Antibody Testing ResultsClinical Chemistry · 2026
- Plasma Cell Counting Methodology Determines Chronic Endometritis Prevalence.Reproductive medicine and biology · 2026
- 200 Enhancing Tumor Grossing Accuracy and Efficiency Using Standardized Checklists Based on CAP ProtocolsAmerican Journal of Clinical Pathology · 2026
- Clustering of patient-derived laboratory data: A privacy-preserving distributed approach to enhance clinical laboratory quality control and regional external quality assessment.PloS one · 2026