B-179 Quantifying the Quality of HEp-2 Cell Slides to Ensure the Accuracy of Indirect Immunofluorescence Antinuclear Antibody Testing Results
D O N G L A I MA, Shanthan Sithravadivel, Mary Bohn, Saranya Arnoldo, Ajauna Herrmann, Pankaj Kumar, Oliver Sendscheid
Key points
From the paper's conclusion- Thus, it is now possible to reliably select the best quality HEp-2 cell slides for ANA testing.
Abstract
Background High-quality HEp-2 cell slides are essential for indirect immunofluorescence antinuclear antibody (ANA) testing. However, there is currently no established method to quantify the substrate quality. This leads to subjective evaluation and affects the selection of high-quality HEp-2 cell slides. Our goal was to establish a method to thoroughly quantify HEp-2 cell slide quality and select the best HEp-2 cell slides for accurate and reliable ANA testing. Methods This study used both visual and Artificial Intelligence (AI) assisted image analysis methods to quantify the quality of HEp-2 slides based on a scoring system. The score system included cell distribution scores (density, cluster, and detachment); cell morphology scores (interphase/mitotic cell appearance, and nuclear/cytoplasmic ratio); mitotic cell scores; quadrant scores; fluorescence scores; and pattern scores. Higher scores represent higher quality. dIFine® M1 manual microscope, dIFine® automated microscope, Sebia ANA HEp-2 slides and another brand of HEp-2 slides from 2 different batches respectively, were used in the validation. Results Quantifying HEp-2 slide quality across different ANA patterns Illustrates high agreement and accuracy between visual and Al-assisted analysis. Comparison of the total scores and the scores for each category can clearly differentiate the quality of HEp-2 cell slides and identify the substrate defects. Sebia ANA HEp-2 slides show significantly higher scores in all categories and present optimal quality for ANA testing. Conclusion This quantification scoring system demonstrates for the first time that a quantitative approach can be used to assess the quality of HEp-2 cells on ANA test slides. Thus, it is now possible to reliably select the best quality HEp-2 cell slides for ANA testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-140 Performance and Workflow Impact of Automated Image Analysis in High-Volume ANA HEp-2 IIF ScreeningClinical Chemistry · 2026
- Development and temporal validation of AI-enhanced HEp-2 indirect immunofluorescence image analysis for specific autoantibody prediction in systemic autoimmune rheumatic diseases.Arthritis & rheumatology (Hoboken, N.J.) · 2026
- B-178 Comparative Performance of ANCA Indirect Immunofluorescence Assays and Concordance of Manual Versus Automated Interpretation in 583 SeraClinical Chemistry · 2026
- Deep learning for automated classification of antinuclear antibody patterns on HEp-2 indirect immunofluorescence images.Immunologic research · 2026
- B-187 Clinical Performance Comparison of Manual, Semi-Automated, and Fully Automated Anti-Nuclear Antibody Immunofluorescent Platforms for Screening Systemic Autoimmune Rheumatic DiseasesClinical Chemistry · 2026
- AI-Assisted Interpretation of Neurologic Autoantibody Cell-Based AssaysmedRxiv · 2026