Effect of Undersized Drilling and Sequential Osseodensification on Primary Implant Stability in Simulated Bone Types III and IV: An In Vitro Study.
Silvio Yoshiaki Okagawa, Alex Sandro de Souza, Paulo Sérgio Perri de Carvalho, Antonio Scarano, Bruno Freitas Mello, Sergio Rexhep Tari, Gustavo Coura, Gustavo Vicentis Oliveira Fernandes,
Department of Implant Dentistry, SLMANDIC - Sao Leopoldo Mandic, Campinas 13045-755, Brazil, slmandic.edu.br. · Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Chieti 66013, Italy, unich.it.
Key points
From the paper's conclusion- The use of sequential osseodensification protocols yielded superior mechanical stability parameters, specifically in IT and RT, in synthetic (polyurethane) bone models. However, improvements in ISQ were predominantly noted in the denser type III model. Importantly, because the tested protocols involved different drill designs and underpreparation dimensions, these enhancements reflect the success of the overall surgical strategy rather than the isolated effect of osseous densification.
Abstract
PURPOSE: Primary implant stability is a key factor for successful osseointegration and may be influenced by osteotomy preparation techniques, particularly in low-density bone. Thus, this study compared undersized drilling (UD), UD combined with osseodensification, and sequential osseodensification protocols with varying degrees of undersizing in simulated bone types III and IV with respect to implant stability. Additionally, the relationships between insertion torque (IT), removal torque (RT), and implant stability quotient (ISQ) were analyzed. MATERIALS AND METHODS: Eighty implants (4.0 × 11 mm) were placed in polyurethane blocks simulating type III and IV bone with a cortical layer. Four osteotomy protocols were tested: UD, UD plus osseodensification (OD1), and sequential osseodensification with -0.5 mm (OD2) and -0.7 mm (OD3) undersizing. Primary stability was assessed using IT, RT, and ISQ measurements. Data were analyzed using two-way ANOVA, Pearson correlation, and multiple regression analysis (α = 0.05). RESULTS: OD2 and OD3 produced higher IT values in both bone types compared with UD and OD1. In type III bone, OD3 showed the highest RT values, while in type IV bone, OD2 and OD3 were significantly higher than UD and OD1. ISQ values were higher for osseodensification protocols in type III bone, whereas no significant differences were observed in type IV bone. A strong correlation was found between IT and RT (r = 0.746), whereas ISQ showed weaker associations with torque. CONCLUSION: The use of sequential osseodensification protocols yielded superior mechanical stability parameters, specifically in IT and RT, in synthetic (polyurethane) bone models. However, improvements in ISQ were predominantly noted in the denser type III model. Importantly, because the tested protocols involved different drill designs and underpreparation dimensions, these enhancements reflect the success of the overall surgical strategy rather than the isolated effect of osseous densification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Primary Stability of Implants Inserted Using Different Osseodensification Systems in Low-Density Bone: An In Vitro StudyDentistry Journal · 2026
- Influence of Different Drilling Protocols for Primary Stability at Low-Density Bone Detected by Bone Density Measurement Drill.Clinical and experimental dental research · 2026
- Effects of osteotomy preparation protocols and implant macrogeometry on primary stability in an ex vivo bovine-rib modelBMC Oral Health · 2026
- Influence of Implant Macrogeometry on Primary Stability in Different Polyurethane Bone-Density Models: An In Vitro Study.Bioengineering (Basel, Switzerland) · 2026
- The Effect of Osseodensification and Conventional Implant Site Preparation on Implant Stability of Tapered and Cylindrical Dental Implants: A Randomized Controlled Study.The Journal of craniofacial surgery · 2026
- Evaluation of the Effects of Dental Implant Dimension and Design on Primary Implant Stability Using Different Stability Measurement Devices.Journal of clinical medicine · 2026