From the paper's conclusion- This in vitro study evaluates the effects of dental implant design, diameter, length, and bone density on primary implant stability using Osstell ISQ and Penguin Resonance Frequency Analysis (RFA) devices.
Abstract
Background/Objectives: Dental implants are an established treatment for functional and aesthetic rehabilitation of partially or completely edentulous patients. This in vitro study evaluates the effects of dental implant design, diameter, length, and bone density on primary implant stability using Osstell ISQ and Penguin Resonance Frequency Analysis (RFA) devices. Materials and Methods: A total of 96 dental implants were included in this study. Combinations of two implant designs (T6 Standard and T6 Torq), two implant diameters (3.5 mm and 5.0/4.8 mm), and two implant lengths (8 mm and 14 mm) were placed into synthetic bone blocks with densities of PCF15 and PCF30. Implant stability was measured twice from two different directions using Osstell ISQ and Penguin RFA devices. The data were statistically analyzed. Results: Both RFA devices demonstrated high measurement reproducibility. When all measurements were evaluated collectively, the intraclass correlation coefficient (ICC) reached 0.999 for both devices. Bone density was identified as the most influential factor affecting primary implant stability. Significantly higher ISQ values were obtained in the high-density bone model (p < 0.001). Increases in implant length and diameter significantly enhanced primary stability (p < 0.001). T6 Torq implants exhibited significantly higher ISQ values than T6 Standard implants in low-density bone and small-dimension implant combinations (p < 0.001). Conclusions: Under the present experimental conditions, bone density showed the greatest influence on primary implant stability, followed by implant length and implant diameter. In low-density bone, particularly with short and narrow implants, more aggressive implant macrodesigns may contribute to higher primary stability. However, the clinical relevance of these findings requires further investigation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Implant Macrogeometry on Primary Stability in Different Polyurethane Bone-Density Models: An In Vitro Study.Bioengineering (Basel, Switzerland) · 2026
- Influence of Implant Macrodesign on Primary Stability Across Different Bone Density Models: A Comparative In Vitro Study.Journal of functional biomaterials · 2026
- Primary Stability of Implants Inserted Using Different Osseodensification Systems in Low-Density Bone: An In Vitro StudyDentistry Journal · 2026
- The Relationship Between Recorded Bone Quality and Primary Implant Stability Measured by Insertion Torque: A Retrospective Study.Cureus · 2026
- The Effect of Osseodensification and Conventional Implant Site Preparation on Implant Stability of Tapered and Cylindrical Dental Implants: A Randomized Controlled Study.The Journal of craniofacial surgery · 2026
- Effect of Progressive Versus Standard Implant Thread Designs on Primary Stability and Insertion Torque: An In Vitro StudyThe International Journal of Oral & Maxillofacial Implants · 2026