Structural behavior of HPC columns reinforced with CFRP bars under axial loading.
Saad M Badr, Ali S Shanour, Taha A El-Sayed, Gamal E Abdelaziz
Structural Engineering Department, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt. · Structural Engineering Department, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt. taha.ibrahim@feng.bu.edu.eg.
Key points
From the paper's conclusion- This study investigates the axial compressive behavior of high-performance concrete (HPC) columns reinforced with carbon fiber-reinforced polymer (CFRP) bars, motivated by CFRP's high strength, fatigue resistance, and corrosion immunity.
Abstract
This study investigates the axial compressive behavior of high-performance concrete (HPC) columns reinforced with carbon fiber-reinforced polymer (CFRP) bars, motivated by CFRP's high strength, fatigue resistance, and corrosion immunity. Despite these advantages, limited research has constrained its practical use. Eight HPC columns (150 × 150 mm cross-section, 1200 mm height) made of M50-grade concrete with 8% silica fume and superplasticizer were tested under axial loading. Key parameters included axial load capacity, deformation, failure mode, and ductility. Results showed that CFRP-reinforced columns exhibited only a slight 5.7% reduction in ultimate load compared to steel-reinforced counterparts. However, CFRP specimens absorbed approximately 8% more energy while maintaining comparable ductility. No CFRP bar rupture occurred during testing; the maximum strain recorded in the longitudinal CFRP bars reached approximately 65% of their ultimate tensile strain capacity (2600 μm/m out of 4000 μm/m). Theoretical strength predictions using existing confined-concrete models aligned with experimental data. Overall, the study demonstrates that CFRP longitudinal bars and stirrups offer a viable alternative to conventional steel reinforcement in HPC columns. The minor reduction in load capacity is offset by improved energy absorption and environmental benefits, including corrosion resistance and potentially longer service life. These findings support broader application of CFRP in concrete structures, particularly where durability under aggressive conditions is critical. The work contributes valuable experimental data and validates analytical models, helping to bridge the knowledge gap hindering wider adoption of CFRP reinforcement in real-world construction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Behavior of FRP‐Reinforced Concrete Columns Subjected to Combined Axial Compression and Lateral LoadingAdvances in Civil Engineering · 2026
- CFRP-Confined Pre-Damaged Recycled Aggregate Concrete Square Columns Under Axial CompressionApplied Sciences · 2026
- Experimental and Analytical Evaluation of Strengthening Techniques for Ultra-High-Performance Concrete Circular Columns.Polymers · 2026
- Cyclic behavior of high-performance concrete columns reinforced with hybrid-GFRP barsProceedings of the Institution of Civil Engineers - Structures and Buildings · 2026
- CFRP sheet-strengthened post-high-temperature square concrete-encased CFST columns: axial mechanical behaviorJournal of Physics: Conference Series · 2026
- Axial Compressive Behaviour of Intermediate-Length Concrete-Filled Steel Tubular Columns with Different CFRP Wrapping ConfigurationsBuildings · 2026