Design and Development of a PC-Based Analyte Detector Using Differential Pulse Voltammetry for Sensing Applications
Aman Dubey, Nitin Dhiman, Bishan Kumar, P. K. Dubey, ANOOP SINGH, Sandeep Arya
Key points
From the paper's conclusion- Therefore, the differential pulse analyte detector is a cost-effective, DPV-optimized, field-deployable sensing platform with future expandability.
Abstract
This work presents a PC-based, DPV-exclusive potentiostat, termed the differential pulse analyte detector, optimized for electrochemical sensing. In contrast to conventional low-cost multifunctional potentiostats, the proposed system employs a DPV-specific design, which minimizes hardware overhead, reduces power consumption, and enhances measurement stability. The system is built around an ATmega16A microcontroller and an MCP4725 digital-to-analog converter, employing fully software-generated DPV waveforms without analog RC-based shaping circuits, thereby ensuring precise timing, enhanced waveform integrity, and long-term stability. A counter-electrode excitation strategy is implemented to maintain reference electrode stability and suppress capacitive background currents. The inclusion of a selectable transimpedance amplifier (1 kΩ–1 MΩ) provides a wide dynamic current range, while the ±2 V operating window exceeds that of several reported low-cost potentiostats such as ESPotensio and HunStat. The analytical performance of the device is validated using malathion as an analyte, achieving a sensitivity of 0.43 μA nM −1 and a limit of detection of 3.34 nM, comparable to a commercial CHI 660E workstation. An intuitive Visual Basic–based graphical user interface further enhances usability for non-expert users. Therefore, the differential pulse analyte detector is a cost-effective, DPV-optimized, field-deployable sensing platform with future expandability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Digital-Based Potentiostat and Mesoporous Microelectrode Co-Design for Non-Enzymatic Glucose Detection at 0.3V- VDD and 1.65nW-Power.IEEE transactions on biomedical circuits and systems · 2026
- Pulseometry: A differential readout to compensate signal drift of potentiometric probes.Science advances · 2026
- Evaluating Analytical Performance of Commercial Screen-Printed Electrodes for Point-of-Care Uric Acid Sensing: A Comparative StudyApplied Sciences · 2026
- A miniaturized drop-based three-electrode system for sensitive electrochemical determination of azathioprine using pencil graphiteScientific Reports · 2026
- Theophylline electrochemical sensing in pharmaceutical drugs using disposable boron-doped diamond thin film electrodesFunctional Diamond · 2025
- Determination of Uric Acid in Human Urine by Differential Normal Pulse Voltammetry With a Bare Glassy Carbon ElectrodeElectroanalysis · 2026