Pulseometry: A differential readout to compensate signal drift of potentiometric probes.
Yaotian Wu, Junyu Zhou, Yu Qin, Eric Bakker
Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland. · Eaglenos Sciences Inc., B2-2, Treehouse Headquarters Cluster, No. 73 Tanmi Road, Nanjing Jiangbei New Area, Nanjing, Jiangsu 210044, China.
Key points
From the paper's conclusion- These results showcase the potential of pulseometry for improving the performance of electrochemical sensing in clinical diagnostics.
Abstract
Ion selective electrodes are widely used sensors in point-of-care testing devices to assay electrolytes in whole blood samples. With single-use system, the first solution contact normally results in an important signal drift that negatively affects measurement accuracy. In this work, we propose an approach coined pulseometry to compensate for signal drift. The potentiometric signal is processed through a differential circuit incorporating RC components of different time constants. The differential potential will remain constant for a slowly drifting baseline, while a rapid potential change will result in a peak-shaped difference signal that may be baseline subtracted and integrated to extract the components information. The method was successfully integrated into mass fabricated, microfluidic test cards used in commercial blood gas electrolyte analyzers. Blood calcium levels from three individuals were measured, giving SDs of 0.008 to 0.024 mM, improving precision by 36 to 67% compared to potentiometry. These results showcase the potential of pulseometry for improving the performance of electrochemical sensing in clinical diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An integrated opto-fluidic miniaturized multimodal spectroscopic sensing platform for multiplexed electrolyte detection in blood serum.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Design and Development of a PC-Based Analyte Detector Using Differential Pulse Voltammetry for Sensing ApplicationsECS Sensors Plus · 2026
- A-400 Development of a rapid point-of-care metabolic human blood panel for Na, K, Cl, and Ca diagnostics using the multimodal Fluxergy analyzerClinical Chemistry · 2026
- Potentiometric Sensors in the Wild: Long-Term Stability, Biofouling, and Calibration Strategies for Environmental Applications.Sensors (Basel, Switzerland) · 2026
- Pulse Oximetry Versus Arterial Co-Oximetry During Exercise: A Systematic Review of Agreement and Sensor Technology Reporting Gaps.Biosensors · 2026
- Preserving Sample, Interface, and Signal Fidelity in Wearable Sweat Electrolyte Monitoring During Exercise.Biosensors · 2026