From the paper's conclusion- This three-electrode system offers several advantages, including the capability to measure analytes by dropping the sample solution on the electrode surface, low construction cost due to the use of pencil lead instead of more expensive materials, reduced chemical consumption, and ease of use compared to conventional three-electrode systems.
Abstract
Abstract An inexpensive three-electrode system, called a polishable triple graphite electrode, was designed and fabricated using pencil graphite for electrochemical measurement of electroactive compounds. During the manufacturing process, two pencil graphite leads as working and auxiliary electrodes and a silver wire as a pseudo-reference electrode were connected to a special connector and embedded in a Teflon tube. Then, epoxy resin was used to fill the empty spaces between the electrodes. To evaluate the electrode’s performance, the cyclic voltammetry technique was first used in hexacyanoferrate (III)/(II) solution in the presence of KCl supporting electrolyte. Then, the fabricated electrode was used for quantitative analysis of azathioprine in tablet samples using the differential pulse voltammetry technique. Additionally, parameters affecting the analytical performance of the electrode for measuring azathioprine, such as buffer type and pH were optimized. Under the optimized conditions, a linear response was obtained for azathioprine in the concentration range of 5.2-147.2 µM, with a 4.6 µM limit of detection. This three-electrode system offers several advantages, including the capability to measure analytes by dropping the sample solution on the electrode surface, low construction cost due to the use of pencil lead instead of more expensive materials, reduced chemical consumption, and ease of use compared to conventional three-electrode systems. The miniature design of this system facilitates the analysis of small volume samples (in the range of several microliters), which is highly advantageous for the examination of rare or costly biological analytes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrochemical detection of carbendazim in food and water samples using a pentapeptide-modified pencil graphite electrodeInternational Journal of Environmental & Analytical Chemistry · 2026
- Design and Development of a PC-Based Analyte Detector Using Differential Pulse Voltammetry for Sensing ApplicationsECS Sensors Plus · 2026
- Voltammetric and flow injection-based determination of propranolol using an electrochemically treated pencil graphite electrode.Analytical methods : advancing methods and applications · 2026
- Evaluating Analytical Performance of Commercial Screen-Printed Electrodes for Point-of-Care Uric Acid Sensing: A Comparative StudyApplied Sciences · 2026
- Analytical quality by design for electrochemical nanostructured screen-printed sensor development: uric acid detection in saliva for diagnosis and monitoring of chronic diseases.Talanta · 2026
- Determination of Uric Acid in Human Urine by Differential Normal Pulse Voltammetry With a Bare Glassy Carbon ElectrodeElectroanalysis · 2026