Afghanite: A New Silicate‐Matrix Reference Material for In Situ Halogen and Sulfur Microanalysis
S. Stumpf, Thomas Pettke, Johannes Hammerli, Michael A.W. Marks, Andreas Audétat, Jaime D. Barnes, J R Dietrich, Renée J. Tamblyn
University of Bern · Washington State University
Key points
From the paper's conclusion- We propose afghanite as a robust silicate reference material for in situ determination of Cl and S for geochemical and petrological applications.
Abstract
Sulfur (S) and the halogens (F, Cl, Br, I) play key roles in geochemical processes that govern volatile cycling, redox evolution, phase reactions and ore formation in the Earth's crust and mantle. Quantifying these elements in situ requires well‐characterised reference materials for calibration and quality control, yet such materials for silicate matrices remain scarce. In this study, we present new data for a suite of gem‐quality crystals of the feldspathoid mineral afghanite and evaluate their potential as a silicate reference material for halogen and S microanalysis. Afghanite incorporates up to ~ 4.5% m/m Cl and S each within its silicate framework. Our results demonstrate that the investigated afghanite crystals are compositionally homogeneous and yield highly precise measurements with excellent agreement between multiple laboratories and analytical methods. LA‐ICP‐MS measurements calibrated with afghanite determine Cl mass fractions in silicate glass reference materials GSE‐1G and NIST SRM 610 within 5% of compiled literature values without any corrections applied. In contrast, when calibrated with scapolite, Cl mass fractions in afghanite and the same silicate glasses are systematically overestimated. To quantitatively evaluate this bias, we introduce the matrix sensitivity factor (MSF), which demonstrates that matrix effects affecting scapolite result in systematic Cl overestimations of 8–13% in other silicate matrices. Sulfur mass fractions in the scapolite control reference material Sc‐1 determined by LA‐ICP‐MS using afghanite as calibrator are within 5% of results obtained by EPMA and matrix‐matched calibrated LA‐ICP‐MS analyses. We propose afghanite as a robust silicate reference material for in situ determination of Cl and S for geochemical and petrological applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- New potential reference materials for in-situ microscale Ag isotope analysis by fsLA-MC-ICP-MS.Talanta · 2026
- In situ Spodumene Li Isotope Ratio Determination by fs‐ LA ‐ MC ‐ ICP ‐ MS : Method Evaluation, Reference Material Development and Geological ApplicationsGeostandards and Geoanalytical Research · 2026
- A Multi-Standard Linear Regression Calibration for SIMS Sulfur Isotope Analysis of PyrrhotiteGeosciences · 2026
- In Situ Rb‐Sr Geochronology of Potassium Feldspars: New Reference Materials and Matrix SensitivityGeostandards and Geoanalytical Research · 2026
- Raman-Based Internal Standardization for Quantitative LA-ICP-MS Analysis of Individual Fluid Inclusions.Analytical chemistry · 2026
- Development of Arsenopyrite Reference Materials (Sacra and Niko) for In situ Multiple Sulfur Isotope MeasurementGeostandards and Geoanalytical Research · 2026